BMC RESmart User Manual

Integrated heated humidifier
Hide thumbs Also See for RESmart:

Advertisement

Quick Links

©
RESmart
Heated Humidifier
User Manual V2.6
Warranty
3B Medical, Inc. warrants that this humidifier shall be free from defects of workmanship and materials and will perform in
accordance with the product specifications for a period of two (2) years from the date of sale by 3B Medical, Inc. to the
dealer. If the product fails to perform in accordance with the product specifications, 3B Medical, Inc. will repair or replace,
RESmart® CPAP/Auto CPAP System
RESmart© Integrated Heated Humidifier
at its option, the defective material or part. 3B Medical, Inc. will pay customary freight charges from 3B Medical, Inc. to the
dealer location only. This warranty does not cover damage caused by accident, misuse, abuse, alteration and other defects
User Manual
User Manual
not related to material or workmanship. To exercise your rights under this warranty, contact your local, authorized dealers
or:
3B Medical, Inc.......................................
3B Medical, Inc.
1142 N. Scenic Highway
P13
Lake Wales, FL 33844 USA
Email: info@3Bproducts.com
Tel: (863) 226-6285 Fax: (863) 226-6284

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RESmart and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BMC RESmart

  • Page 1 (2) years from the date of sale by 3B Medical, Inc. to the dealer. If the product fails to perform in accordance with the product specifications, 3B Medical, Inc. will repair or replace, RESmart® CPAP/Auto CPAP System RESmart© Integrated Heated Humidifier at its option, the defective material or part.
  • Page 2: Table Of Contents

    Integrated Heated Humidifier is designed only for use with specific BMC The RESmart is intended for use in the electromagnetic environment specified below. The user of the RESmart should make sure that it is used in such an environment. ®...
  • Page 3: Warnings & Cautions

    IMPORTANT! • Read all instructions before using the humidifier. The RESmart is intended for use in the electromagnetic environment specified below. The user of the • Use only with BMC RESmart devices whose instructions specify the use of this humidifier.
  • Page 4: Features

    User Manual V2.6 EMC Requirements Guidance and manufacturer's declaration - electromagnetic emissions The RESmart is intended for use in the electromagnetic environment specified below. The user of the RESmart should ensure that it is used in such an environment. Emissions Test...
  • Page 5: Set Up

    1. Connect the Humidifier to the RESmart device. Make sure they are connected completely. Degree of Protection Against Ingress of Water 2. Place the RESmart device and humidifier on a firm, flat surface at a level lower than your sleeping position. IPX1 –Drip-Proof, Vertical Heater Settings 1 to 5 (104 to 149°...
  • Page 6: Daily Use

    Avoid moving or tilting the humidifier when the water chamber has water in it. the humidifier. DO NOT immerse the humidifier into any fluids. 4. Press the humidifier button on the RESmart device after CPAP is blowing. The humidifier key will be lighted and the Water Chamber yellow indicator light on the humidifier will turn on.

Table of Contents