1. Be sure mounting surface is
clean and dry. Align deck gasket
(22) as shown, then assemble
the deck gasket (22) to the
faucet assembly, pushing the
gasket around the mounting
studs (19) until it is seated inside
the bottom lip of the escutcheon.
A
1
3
14
4
5
6
7
16
8
9
13
1. Place plumber's putty (14) under seat (3).
2. Thread mounting nut (6), washer (5) and bottom
gasket (4) onto drain body (7). Wrap top threaded
end of drain body with Teflon tape (16).
3. Position drain body up through drain opening and
screw seat onto drain body.
4. Align the drain body so that the pivot rod opening
faces the rear of the sink and tighten the mounting
nut snug.
5. Apply Teflon tape to the threaded end of tailpiece
(13) and screw into the drain body. Tighten firmly by
hand.
6. Drop in drain plug (1) and install pivot rod in one of
the following ways:
(A) VANDALPROOF: Prevents unauthorized removal
of drain plug. Place pivot rod seat (8) into opening of
drain body as shown. Place the pivot rod (15) into the
MASKING
TAPE
11
1
4
3
5
2
7
6
8
9
2
22
23
3/4"
(19mm)
CAUTION: Severe bends of the supply lines may cause crimping and restricted
water flow could result. If using flexible supply lines (not included) thread supply
line nuts onto tailpiece adapter (20) finger-tight, then holding tailpiece adapter with
wrench, tighten supply line nut with another wrench, rotating one half turn.
2. Install clamp bars (23) (channel facing up), spacers (24) and mounting nuts
(25). Tilt clamp bar back as shown, then install faucet with supplies attached
down through deck.
(Note: on decks thicker than 3/4" (19mm) do not use spacer).
2
1 Drain Plug
9 Pivot Nut
2 Lift Rod & Knob
10 Lift Rod Strap
3 Seat
11 Lift Rod Strap Screw
4 Bottom Gasket
12 Spring Clip
5 Mounting Washer
13 Tailpiece
6 Mounting Nut
14 Plumber's Putty
11
7 Drain Body
15 Pivot Rod
10
8 Pivot Rod Seat
16 Teflon Tape
1
15
12
15
(A)
opening and position the pivot rod through the drain
plug hole as shown in illustration (A) above. Slide the
pivot nut (9) onto the pivot rod and thread it snugly onto
the drain body, be careful not to overtighten.
(B) EASY REMOVAL: For quick removal of drain plug
for cleaning, follow instructions above except position
parts as shown in illustration (B) above.
7. With lift rod (2) in position on the faucet, insert the
end into the lift rod strap (10) and secure with lift
rod strap screw (11).
8. Connect the pivot rod (15) to lift rod strap using
spring clip (12) as shown above.
9. Place the drain plug in the full open position, loosen
lift rod strap screw and adjust the lift rod height so
that the knob clears the faucet. Tighten the lift rod
strap screw. Installation is now complete.
MASKING
TAPE
Align left edge of
stop ring with the
mark on the
MARK
MASKING
masking tape.
TAPE
24
25
20
1
15
(B)
Setting Adjustable Temperature Limit Stop
Determine Desired Temperature
1. Apply masking tape to the collar (11) in the
upper right hand quarter (12 o'clock to 3
o'clock).
2. Turn on faucet until hot water temperature
stabilizes, set the handle to the desired
maximum temperature, close the valve
handle keeping it in the desired position.
3. Draw an imaginary line through the center
line of the handle and mark this position on
the masking tape, see illustration.
Setting Desired Temperature
1. Remove plug button (3), set screw (2) and
handle (1).
2. Remove handle screw (4) and handle
adapter (5).
3. Remove retaining clip (9) and temperature
limit stop ring (7) from the pivot retainer
(8).
4. Replace temperature limit stop ring on
pivot retainer, aligning left side of limit stop
ring notch with pencil mark on masking
tape.
3. Check faucet and gasket position
3
and tighten mounting nuts (25) from
below.
Connect flexible supply lines to your
existing hot and cold water supply lines.
IF YOU ARE NOT INSTALLING A
WASTE ASSEMBLY, faucet installation is
now complete.
required. See faucet flushing instructions
under maintenance section on page 3.
IF YOU ARE INSTALLING A WASTE
ASSEMBLY,
instructions A below.
IF YOU ARE INSTALLING A MOEN
GRID
WASTE,
instructions B below.
B
1
1
2
7
3
4
5
2
3
6
4
7
5
8
8
6
1. Place plumber's putty (7) under seat (1).
2. Thread mounting nut (4), washer (3) and bottom gasket
(2) onto drain body (5). Wrap top threaded end of drain
body with Teflon tape (8).
3. Position drain body up through drain opening and screw
seat onto drain body.
4. Apply Teflon tape (8) to the threaded end of tailpiece (6)
and screw into the drain body (5). Tighten firmly by hand.
Wipe any excess putty from the drain area in the bowl.
5. Slip retaining clip onto pivot retainer to
hold stop ring in position.
6. Replace handle adapter (making sure that
pivot pin is located in pivot slot), place
handle screw in handle adapter and
tighten.
7. Replace handle and set screw. Tighten set
screw and replace plug button.
8. Check for proper position of adjustable
temperature limit stop by running faucet
with handle full ON and turned to the stop.
To readjust repeat the disassembly steps
above. Remove the stop ring
pivot retainer, rotate it clockwise to
increase, counterclockwise to decrease
temperature and replace. Replace handle
components and recheck for desired
temperature.
Due to seasonal change of the cold water
supply, or changes to the setting of the hot
water supply, the temperature limit stop must
be readjusted accordingly to maintain the
desired maximum discharge temperature.
Faucet flushing is
go
to
installation
go
to
installation
Seat
Bottom Gasket
Mounting Washer
Mounting Nut
Drain Body
Tailpiece
Plumber's putty
Teflon Tape
from the
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

84328434

Table of Contents