Remote reception is insensitive or fails.
Remote reception is
insensitive or fails.
Check whether the remote
control works properly.
Check whether the power
supply voltage to the remote
censor is normal.
Use an oscilloscope to check whether
there is output waveform from the first pin IR
of the remote censor after pressing button
on the remote control.
Check whether there is IR
signal on pin 71 of U3
Fix connection
Go
Yes
Yes
Yes
No
4-9
No
Check battery
No
Check R317 C303 C304
No
U201(PIN 3 - RC waveform)
Yes
Replace U3
IR waveform