Flat Roof System - Shading - Daikin EKSV21P Planning And Installation Instructions

Pressurised solar system
Hide thumbs Also See for EKSV21P:
Table of Contents

Advertisement

6.5 Flat roof system – Shading
Distance z [m] depending on gradient angle 
Latitude
30°
56
7.13
54
6.24
52
5.60
50
5.11
48
4.72
46
4.41
44
4.15
42
3.93
40
3.74
38
3.57
36
3.43
Tab. 6-5 Measurement z with shading
α
z
Fig. 6-2
Shading
EKSV21P + EKSV26P + EKSH26P
DAIKIN Solar P-SYS
008.1629544_01 – 12/2016
EKSV26P
40°
50°
55°
8.47
9.55
9.99
7.33
8.20
8.54
6.50
7.21
7.48
5.87
6.46
6.68
5.37
5.86
6.04
4.97
5.38
5.53
4.64
4.98
5.10
4.35
4.65
4.74
4.11
4.36
4.43
3.90
4.11
4.16
3.71
3.89
3.93
α
Distance z [m] depending on gradient angle 
60°
30°
40°
10.35
4.63
5.50
8.81
4.06
4.77
7.70
3.64
4.23
6.85
3.32
3.82
6.18
3.07
3.49
5.63
2.86
3.23
5.18
2.70
2.01
4.80
2.55
2.83
4.47
2.43
2.67
4.19
2.32
2.53
3.94
2.23
2.41
6
x
Technical data
EKSH26P
50°
55°
60°
6.21
6.49
6.72
5.33
5.55
5.73
4.69
4.86
5.00
4.20
4.34
4.45
3.81
3.93
4.01
3.50
3.59
3.66
3.24
3.32
3.37
3.02
3.08
3.12
2.83
2.88
2.91
2.67
2.71
2.72
2.53
2.55
2.56
Planning and installation instructions
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eksv26pEksh26p

Table of Contents