Philips CEM2000/00 Service Manual page 69

Hide thumbs Also See for CEM2000/00:
Table of Contents

Advertisement

9.2 AM IF-processing
9.1.1 Channel selection filter
Symbol
Parameter
CSF BW
Channel selection filter BW
9.2.1 Soft mute
(continuous set)
Symbol
Parameter
SMsp
Start point vs. field strength
SMep
End point vs. field strength
SMd
Depth
Transition time for field
SMtauatt
strength-dependent soft mute
activation
Transition time for field
SMtaurel
strength-dependent soft mute
release
9.2.2 High cut control
(continuous set)
Symbol
Parameter
HCFSsp
Start point vs. field strength
HCFSep
End point vs. field strength
Field strength-related
HCFStW2N
transition time from wide to
narrow band
Field strength-related
HCFStN2W
transition time from narrow to
wide band
Maximum cut-off frequency of
HCmaxBW
high cut filter bank
Minimum cut-off frequency of
HCminBW
high cut filter bank
HCnumFilt
Number of discrete HC filters
Test Condition, Comments
response: - 3dB
Test Condition, Comments
audio atten = 1 dB
read "FM_softmute"
no adjacent channel present
audio atten = SMd + 1 dB
read "FM_softmute"
no adjacent channel present
Test Condition, Comments
minimum RF level for widest
HC filter (filter # 7)
no multipath present
maximum RF level for
narrowest HC filter (filter # 0)
no multipath present
Vrf step-like variation from 60
dBu to 10 dBu
Vrf step-like variation from 0
dBu to 60 dBu
Filter #7, -3 dB response
frequency, input signal with
pre-emphasis
Filter #0, -3 dB response
frequency, input signal with
pre-emphasis
-
Rev. 1.0
TDA7703/TDA7703R
Range
Min
Typ
Max
-
±3.7
-
Range
Min
Typ
Max
0
25
40
0
0
30
-40
-24
0
0.001
0.1
10
0.001
3
10
Range
Min
Typ
Max
0
40
50
0
30
50
0.001
0.2
20
0.001
10
20
HCmin
TBD
TBD
BW
HCma
TBD
TBD
xBW
-
8
-
Units
kHz
Units
dBu
dBu
dB
s
s
Units
dBu
dBu
s
s
kHz
kHz
-
19/22