Installation Requirements And Recommendations; Rack Requirements - Mitel 2000 Series Hardware Installation Manual

Table of Contents

Advertisement

1.4
Installation Requirements and
Recommendations
Before installing a Mobility Router, follow these requirements and recommendations.
1.4.1 Installation Location Guidelines
The Mobility Router should be installed in an environment sufficient for normal operation of network appliances
(50-95°F). Make sure that the area allows for enough ventilation after the Mobility Router is installed. The
appliance should be installed in an area that does not exceed the following humidity range: 8-90%
non-condensing.

1.4.2 Rack Requirements

The Mobility Router must be installed in a standard 19-inch rack. Make sure that the Mobility Router is installed in
the rack so that the Mobility Router is level in the rack and is fastened by screws on both sides. Refer to
the Mobility Router" on page 6
1.4.3 Required Equipment for Installation
The following equipment is required for rack installation (and depends on the type of rack):
Mounting screws to rack mount the Mobility Router (not provided)
Screwdriver (not provided)
1.4.4 Uninterruptible Power Supply
We recommend installing the Mobility Router in an existing Uninterruptible Power Supply (UPS) infrastructure.

Installation Requirements and Recommendations

for installation instructions
Mobility Router 2000 Series Hardware Installation Guide
Mobility Router 2000 Installation