Table A–1 Internal Status Codes - Quantum DLT 7000 Product Manual

Tape system
Hide thumbs Also See for DLT 7000:
Table of Contents

Advertisement

DEFINITION OF VENDOR UNIQUE SENSE DATA
This appendix lists the internal status codes with their descriptions.
The internal status code is located at byte offset 18 of the REQUEST SENSE
data and may be available for certain types of failures.
Byte 18 of the REQUEST SENSE data has two formats: a byte code
and a bit flags format. The bit flags format is used when there is no
internal status code to report and can be quickly distinguished by
checking to see if bit 7 of byte 18 is set to 1.
Decimal
Hexadecimal
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
0A
NOTE
Table A–1 Internal Status Codes
Description
No Meaning
Reed-Solomon Error Correction Code Recovery
READ or WRITE Block Retry (Soft Retry)
REPOSITION Command Aborted
Controller Has Stopped Reading
No Control or Data Buffers Available
Target Delivered in Read Ahead
Logical EOT Encountered, 2 Filemarks
Command Connection Dropped
Cleared from Queue
Missing Data Block – READ only
Quantum DLT 7000 Tape System
Appendix A
INFORMATION
A-1

Advertisement

Table of Contents
loading