  • Page 1: Air Compressor

    AIR COMPRESSOR OPERATOR'S MANUAL CAUTION RISK OF INJURY! READ ENTIRE ® MANUAL BEFORE OPERATING! THIS MANUAL IS AN IMPORTANT PART OF THE AIR COMPRESSOR AND MUST REMAIN WITH THIS UNIT! ©Copyright 2012, Mi-T-M Corporation® 37-1210-E/S-060914...
  • Page 2: Table Of Contents

    MAINTENANCE INSTRUCTIONS ................... 15 TROUBLESHOOTING ....................16-19 WARRANTY ........................20 Warning: This product contains lead, a chemical known to the State of California to cause birth defects or other reproductive harm. Wash your hands after handling this product. Mi-T-M Electric Air Compressor Manual...
  • Page 3: Introduction

    Inspect for signs of obvious or concealed freight damage. If damage does exist, file a claim with the trans- portation company immediately. Be sure that all damaged parts are replaced and the mechanical and electrical problems are corrected prior to operation of the unit. If you require service, contact your Mi-T-M ®...
  • Page 4: Important Safety Instructions

    Allow air compressor to cool down. Never assume the air compressor is safe to work on just because it is not operating. It could restart at any time! Service in a clean, dry, flat area. Mi-T-M Electric Air Compressor Manual...
  • Page 5: Risk Of Explosion Or Fire

    Because of extreme heat, do not result in serious injury. use plastic pipe or lead tin soldered joints for a discharge line. Never use air compressor to inflate small, low pressure objects such as toys. Mi-T-M Electric Air Compressor Manual...
  • Page 6: Risk To Breathing

    Serious injury can occur from loose people and animals while operating debris being propelled at a high the air compressor. speed from the compressed air stream. Do not attempt to move the air compressor by pulling on the hose. Mi-T-M Electric Air Compressor Manual...
  • Page 7: Risk From Moving Parts

    Do not operate air compressor in a corrosive environment. Always operate the air compressor in a stable, secure position to prevent air compressor from falling. Follow all maintenance instructions listed in this manual. !SAVE THESE INSTRUCTIONS! Mi-T-M Electric Air Compressor Manual...
  • Page 8: Features Drawings

    4. Pressure Switch 5. Pickup Handle 6. Pressure Regulator 7. Outlet Pressure Gauge 8. Air Tank Drain Valve 9. Air Intake Filter 10. Pump Discharge Line 11. Oil Dipstick 12. Pump Oil Drain 13. Safety Relief Valve Mi-T-M Electric Air Compressor Manual...
  • Page 9: Features Review

    OUTLET PRESSURE GAUGE: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less or equal to the air tank pressure. Mi-T-M Electric Air Compressor Manual...
  • Page 10 It is recommended this air compressor not be operated at more than a 50% duty cycle. This means an air compressor that pumps air longer than 50% of one hour is considered misuse. Maximum air compressor pumping time per hour is 30 minutes. Mi-T-M Electric Air Compressor Manual...
  • Page 11 DO NOT ATTEMPT TO OPERATE THIS AIR COMPRESSOR UNTIL YOU HAVE READ AND UNDERSTOOD ALL SAFETY PRECAUTIONS AND INSTRUCTIONS LISTED IN THIS MANUAL. INCORRECT OPERATION OF THIS UNIT CAN CAUSE SERIOUS INJURY!! DO NOT ALTER OR MODIFY THIS EQUIPMENT IN ANY MANNER! Mi-T-M Electric Air Compressor Manual...
  • Page 12: Preparation Instructions

    -- grasp the plug. into an appropriate outlet that is 6. Always shut off the compressor pressure switch before unplugging the properly installed and grounded compressor. in accordance with all local codes and ordinances. Mi-T-M Electric Air Compressor Manual...
  • Page 13 PREPARATION INSTRUCTIONS NOTE: BEFORE OPERATING, THE FOLLOWING OPERATIONS NEED TO OCCUR. 1. Remove shipping plugs 2. Install oil/vent plug 3. Install Rubber Feet *Refer to 20 Gallon Vertical Tank Foot Assembly (sheet enclosed) Mi-T-M Electric Air Compressor Manual...
  • Page 14: Operating Instructions

    EXAMPLES OF POSSIBLE CORD PLUGS AND CORRESPONDING RECEPTACLE 125V 250V (5-20) (6-15) GROUNDED 5-20R 5-20P 6-15R 6-15R OUTLET GROUNDED OUTLET BOX GROUNDING 250V 3 250V (5-20) (15-30) L15-30R L15-30P 6-50R 6-50P Mi-T-M Electric Air Compressor Manual...
  • Page 15: Maintenance Instructions

    *The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3 months, whichever comes first. In harsh environments, maintenance must be performed on a more accelerated schedule. Every 2 years, an Authorized Service Technician should check the check valve, intake valves and delivery valves. Mi-T-M Electric Air Compressor Manual...
  • Page 16: Troubleshooting

    Use additional air hose instead of wire gauge. extension cord, or use proper cord length or wire gauge. Loose electrical connection. Contact qualified electrician. Oil weight too heavy. Use lighter weight oil. Defective check valve or pressure Replace. switch. Mi-T-M Electric Air Compressor Manual...
  • Page 17 Check connections for air bubbles. Tighten the connections where leaks are present. Defective check valve. Remove, clean or replace. Air leak in air tank. Air tank must be replaced. Do not attempt to repair air tank! Mi-T-M Electric Air Compressor Manual...
  • Page 18 Operate safety relief valve manual- Air leaks from safety relief valve. valve. ly by pulling on ring. If it still leaks, it should be replaced. Excessive air tank pressure. Defective pressure switch. Reset or replace. Mi-T-M Electric Air Compressor Manual...
  • Page 19 Contact your Mi-T-M Customer ® Worn piston rings or scored Service. cylinder. Oil has milky appearance. Water in oil due to Change oil and move air compres- sor to a less humid environment. condensation. Mi-T-M Electric Air Compressor Manual...
  • Page 20: Warranty

    4. Labor charges, loss or damage resulting from improper operation, maintenance (other than routine air tank draining and oil changes, if applicable) or repairs made by persons other than a Mi-T-M Authorized Service Center. 5. The use of other than Genuine Repair Parts will void warranty. Parts returned, prepaid to our factory or to an Authorized Service Center will be inspected and replaced free of charge if found to be defective and subject to warranty.
  • Page 21 NOTES Mi-T-M Manuel Compresseur d'air...
  • Page 22 Californie comme étant la cause de cancer et de malformations congénitales ou autres effets nocifs de reproduction. Laver vos mains après avoir manipulé ce produit. Mi-T-M Manuel Compresseur d'air...
  • Page 23: Introduction

    électriques corrigés avant l'utilisation de l'appareil. Si vous avez besoin d'assistance, entrez en contact avec votre service clientèle. Mi-T-M® Corporation, 8650 Enterprise Drive, Peosta, IA 52068 1-800-553-9053 / Fax 563-556-1235 Monday - Friday 8:00 a.m. - 5:00 p.m. CST Veuillez avoir les informations suivantes disponibles pour toute intervention: Numéro de modèle...
  • Page 24: Importantes Consignes De Securite

    à l'arrêt. Il pourrait se remettre en marche à tout moment! Tout travail doit s'effectuer dans un endroit propre, sec et plat. Mi-T-M Manuel Compresseur d'air...
  • Page 25: Risque D'explosion Ou D'incendie

    à l'étain/fer pour la conduite de décharge. Ne jamais utiliser le compresseur pour gonfler de petits objets à faible pression tels que les jouets d'enfants. Mi-T-M Manuel Compresseur d'air...
  • Page 26: Risque De Problémes Respiratoires

    à grande vitesse par le jet d'air comprimé. Ne jamais deplacer le compresseur lorsque le réservoir d'air est sous pression. N'essayer pas de deplacer l'appareil en tirant sur le tuyau. Mi-T-M Manuel Compresseur d'air...
  • Page 27: Risque Provenant De Pièces Mobiles

    Ne pas utiliser le compresseur dans un environnement corrosif. Ne faire fonctionner le compresseur que lorqu'il est en position stable et ferme afin d'éviter la chute de l'appareil. Veuillez lire toutes les instructions d'entretien contenues dans ce manuel. !GARDER CES INSTRUCTIONS! Mi-T-M Manuel Compresseur d'air...
  • Page 28: Dessins Des Composants

    7. Manométre de sortie 8. Robinet de purge du réservoir 9. Filtre d’admission d’air 10. Conduite de décharge de la pompe 11. Jauge du niveau d’huile 12. Bouchon de vidange d’huile de la pompe 13. Soupape de sûreté Mi-T-M Manuel Compresseur d'air...
  • Page 29: Revue Des Composants

    MANOMETRE DE SORTIE: Le manomètre de sortie indique la pression d’air disponible du côté de la sortie du régulateur. Cette pression est contrôlée par le régulateur et est toujours moindre ou égale à la pression du réservoir. Mi-T-M Manuel Compresseur d'air...
  • Page 30 Ceci signifie qu’un compresseur d’air qui pompe de l’air plus de 50% d’une heure est considéré comme étant mal utilisé. Le durée maximale de pompage d’un compresseur est de 30 minutes par heure. Mi-T-M Manuel Compresseur d'air...
  • Page 31 COMPRESSEUR D'AIR AVANT D'AVOIR LU ET COMPRIS TOUTES LES PRECAUTIONS ET CONSIGNES DE SECURITE CONTENUES DANS CE MANUEL. L'UTILISATION INAPPROPRIEE DE CET APPAREIL PEUT CAUSER DES BLESSURES SERIEUSES!! NE PAS ALTERER OU MODIFIER CET EQUIPEMENT EN AUCUNE MANIERE! Mi-T-M Manuel Compresseur d'air...
  • Page 32: Instructions De Preparation

    5. Tenir les fils électriques et rallonges à l'écart de la chaleur et des bords de masse. coupants. Ne tirer sur aucun fil pour débrancher une prise -- empoigner la prise. 6. Eteigner toujours l'interrupteur de pression du compresseur avant de débrancher le compresseur. Mi-T-M Manuel Compresseur d'air...
  • Page 33: Points De Contrôle Avant Démarrage

    5. S’assurer que toutes les gardes et caches de protection sont en NOTE : AVANT L'OPÉRATION, LA NÉCESSITÉ SUIVANTE D'OPÉRATIONS DE SE PRODUIRE. 1. Enlevez les prises d'expédition 2. Installez la prise d'huile/passage 3. Installez Base *Voir la feuille d'Assemblée de 20 Gallon Vertical Tank (papier inclus) Mi-T-M Manuel Compresseur d'air...
  • Page 34: Instructions D'utilisation

    EXEMPLES DES FICHES POSSIBLES DE CORDE ET DE LA DOUILLE CORRESPONDANTE 125V 250V (5-20) (6-15) SORTIE AU 5-20R 5-20P 6-15R 6-15R BOÎTE DE SORTIE FONDÉE PIQUET DE MISE À 250V 3 250V LA TERRE (5-20) (15-30) 6-50R 6-50P L15-30R L15-30P Mi-T-M Manuel Compresseur d'air...
  • Page 35: Instructions D'entretien

    200 heures ou 3 mois, selon la limite qui est atteinte en premier. Tous les 2 ans, un technicien de service autorisé doit vérifier la soupape de retenue, les soupapes d'approvisionnement et les soupapes de distribution. Mi-T-M Manuel Compresseur d'air...
  • Page 36: Depannage

    Enlever et nettoyer ou remplacer. Le clapet de retenue de la valve pilote est bloqué en position ouverte. Contacter votre service clientèle. Moteur ou interrupteur Moteur/Pression défectueux. Mi-T-M Manuel Compresseur d'air...
  • Page 37 Fuite d'air à la soupape de sûreté manuellement en tirant sur défectueuse. sûreté. l'anneau. Si elle fuit toujours, elle devrait être remplacée. Remplacer l'interrupteur Moteur/Pres- Pression excessive du réservoir sion. Nettoyer, réinitialiser ou rem- d'air. placer la soupape pilote. Mi-T-M Manuel Compresseur d'air...
  • Page 38 Resserrer les boulons de pompe à L'huile fuit. un serrage de couple comme indi- qué dans le manuel des pièces de rechange, ou remplacer les joints. Contacter votre service de cli- Segments usés ou cylindre rayé. entèle. Mi-T-M Manuel Compresseur d'air...
  • Page 39 Rechercher d'éventuelles Fuite d'air dans le réservoir. bulles d'air aux raccords. Resserrer les raccords là où se trouvent les fuites. Enlever, nettoyer our remplacer. Le réservoir d'air doit être remplacé. N'essayer pas de réparer le réservoir. Mi-T-M Manuel Compresseur d'air...
  • Page 40: Bon De Garantie

    çi-dessus. Pour service ou considération de garantie, contacter Mi-T-M Corporation, 8650 Enterprise Drive, Peosta, IA 52068 ® 563-556-7484 / 800-553-9053 / Fax 563-556-1235 du lundi au vendredi de 8h00 à 17h00, CST(heure centrale) Mi-T-M Manuel Compresseur d'air...
  • Page 41 Mi-T-M Manuel Compresseur d'air...
  • Page 42 Manufactured by Mi-T-M 8650 Enterprise Drive, Peosta IA 52068 563-556-7484/ Fax 563-556-1235 Mi-T-M Manuel Compresseur d'air...