Remington REM-B200LT-F User's Manual And Operating Instructions page 23

Vent-free gas heater
Table of Contents

Advertisement

Available languages

Available languages

INSPECTING BURNERS
Check the pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 20 shows a correct pilot flame pattern. Figure 21 shows an incorrect pilot flame pattern. The
incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the
thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 21:
• Turn the heater off (see TO TURN OFF GAS TO THE HEATER, pages 21–22).
• See the TROUBLESHOOTING GUIDE,
Fig. 20—Correct Pilot Flame Pattern
WARNING
©2017 Pinnacle Climate Technologies
page
Do not allow fans to blow directly into the heater. Avoid any drafts that alter
burner flame patterns.
Operation (cont.)
25.
23
Fig. 21—Incorrect Pilot Flame Pattern
Vent-Free Gas Heater User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents