6. ADJUSTMENT

6.1 CONNECTION DIAGRAM

A
B

6.2 TEST MODE

[1] + [6] + [DISC]: 3 times
DIAG IN
All-element lighting
C
[UP]
TOYOTA DIAG Mode In
P190
TOYOTA DIAG Mode In
D
[DISC]: for 1.7 seconds
or ACC off
DIAG End
Normal display
To the Normal Mode
E
Notes:
*1) Note that the test mode is cancelled in the system microcomputer
by switching the ACC OFF and ON, but that it is not in the CD microcomputer.
Use the reset function for complete cancellation of the test mode.
F
60
1
2
Head unit
FH-M8047ZT/XN/ES
FH-M8147ZT/XN/ES
FH-M8047ZT/XIN/ES
FH-M8147ZT/XIN/ES
[DISC] + [UP]
PBUS Test Mode In
PBUS TEST
[DISC]: for 1.7 seconds
DIAG End
[DISC]
CD On
"CD"PICT
To the CD Test Mode
Rest the Microcomputer to
returning to the normal
mode.(*1)
FH-M8047ZT/XN/ES
2
3
GGF-146
Power supply cable
[3] + [DOWN]
Error number displayed
CD ERRXX
To the TOYOTA DIAG Mode
3
4
4