34 Troubleshooting
Figure 127
Troubleshooting suggestions for
System Parameters list (default settings)
There are 4 basic configurations within the DHW mode, selected by parameter DHW configuration (see Parameters list, Num.
1). Default value is 1 and it represents configuration 1. By changing DHW configuration (see Parameters list, Num. 1), all the data
will be automatically set at default condition. Parameters that will be changed according to the DHW mode are numbered from 9
to 46 (see Parameters list). All the parameters can be accessed with a communication package running on the PC. Some param-
eters are available by the installer TSP mode on the MMI or by the OT Room unit.
Table 5
AquaBalance
Category
Description
Num. Address
DHW boiler type
1
System
2
End user setting
3
End user setting
4
End user setting
5
End user setting
6
Exhaust protection
7
Firmware version
8
'+: FRQ¿J 
9,1
'+: FRQ¿J 
10,1
'+: FRQ¿J 
11,1
'+: FRQ¿J 
12,1
'+: FRQ¿J 
13,1
'+: FRQ¿J 
14,1
'+: FRQ¿J 
15,1
'+: FRQ¿J 
16,1
'+: FRQ¿J 
17,1
'+: FRQ¿J 
18,1
'+: FRQ¿J 
19,1
'+: FRQ¿J 
20,1
'+: FRQ¿J 
21,1
'+: FRQ¿J 
22,1
'+: FRQ¿J 
23,1
'+: FRQ¿J 
24,1
'+: FRQ¿J 
25,1
'+: FRQ¿J 
26,1
'+: FRQ¿J 
27,1
'+: FRQ¿J 
28,1
'+: FRQ¿J 
29,1
'+: FRQ¿J 
30,1
'+: FRQ¿J 
31,1
'+: FRQ¿J 
32,1
'+: FRQ¿J 
33,1
'+: FRQ¿J 
34,1
'+: FRQ¿J 
35,1
Part number 550-100-305/0118
M
-
ALL
OUNT GAS
FIRED WATER BOILER
(continued)
AquaBalance
list of System parameters (default settings)
E2 prom parameters
Description
CL5 – 05C8
'+: FRQ¿JXUDWLRQ
ML – 80D0
)LUVW VWDUWXS ÀDJ
ML – 80E2
Summer / Winter selection
ML – 80E3
Economy / Comfort selection
CL5 – 0A9D
CH set point limit - HIGH
CL5 – 056D
CH user set point
CL5 – 050B
Maximum exhaust gases temperature
ML – 80E8
Firmware version
CL5 – 066E
DHW P factor
CL5 – 0691
DHW I factor
ML – 80EB
DHW FF factor
ML – 80EC
Fan absolute DHW maximum speed
ML – 80ED
Fan absolute CH maximum speed
ML – 80EE
Fan absolute minimum speed
CL5 – 2D89
Fan offset low level
ML – 80F0
Ignition level
ML – 80F1
DHW maximum output boost/limit level
ML – 80F2
DHW maximum output boost/limit time
ML – 80F3
'+: RYHUWHPSBEXUQHU2))  ¿[HG
ML – 80F4
'+: RYHUWHPSBEXUQHU21  ¿[HG
ML – 80F5
DHW over-temp_burnerOFF – setpoint
ML – 80F6
DHW over-temp_burnerON – setpoint
ML – 80F7
DHW over-temp_burnerOFF – solar
ML – 80F8
DHW over-temp_burnerON – solar
ML – 80F9
DHW start waiting time – solar1
ML – 80FA
DHW start waiting time – solar2
ML – 80FB
DHW start waiting time – solar3
CL5 – 0A5E
DHW comfort switch on point
CL5 – 0A62
DHW comfort on time
ML – 80FE
DHW comfort off time1
ML – 80FF
DHW comfort off time2
CL5 – 05A1
DHW OFF time
CL5 - 0A04
DHW pump over-run time
CL5 – 0A6D
Delta T1
CL5 – 0A92
Delta T2
Boiler Manual
boilers — Fault displays and diagnostics
(continued)
Unit
Range
Low
High
Num
1
4
Num
0
1
Num
0
1
Num
0
1
°F
68
194
°F
68
194
°F
32
255
Num
0
99
Num
0
255
Num
0
255
Num
0
255
Hz
0
220
Hz
0
220
Hz
0
165
Hz
0
220
%
0
100
%
75
125
Sec
0
120
°F
68
194
°F
68
194
°F
0
200
°F
0
200
°F
0
200
°F
0
200
Sec
0
255
Sec
0
255
Sec
0
255
°F
0
176
Sec
0
104
Min
0
255
Min
0
255
Sec
30
255
Sec
0
255
°F
0
108
°F
0
255
Def
Value
3
0
1
0
190
158
185
03
15
240
0
200
200
40
10
60
100
60
167
163
9
0
18
18
5
10
20
104
15
20
42
120
3
32
63
99