Panasonic S-15MK2E5A Installation Instructions Manual

Vrf system air conditioner
Hide thumbs Also See for S-15MK2E5A:

Advertisement

INSTALLATION INSTRUCTIONS

– VRF System Air Conditioner –
for Refrigerant R410A
■ R410A Models
Model No.
Indoor Units
Rated Capacity
Indoor Units
Type
Type
15
22
28
36
K2
Wall Mounted S-15MK2E5A S-22MK2E5A S-28MK2E5A S-36MK2E5A
ENGLISH
Read through the Installation Instructions before you proceed with the installation.
In particular, you will need to read under the "IMPORTANT!" section at the top of the page.
FRANÇAIS
Lisez les instructions d'installation avant de commencer l'installation.
En particulier, vous devez lire la section "IMPORTANT!" en haut de la plage.
ESPAÑOL
Lea las Instrucciones de instalación antes de proceder con la instalación del equipo.
En concreto, deberá leer detenidamente la sección "¡IMPORTANTE!" situada al principio de la página.
DEUTSCH
Lesen Sie die Einbauanleitung, bevor Sie mit der Installation beginnen.
Insbesondere die Hinweise im Abschnitt "WICHTIG!" oben auf der Seite müssen unbedingt gelesen werden.
ITALIANO
Leggere le Istruzioni di installazione prima di procedere con l'installazione.
Prestare particolare attenzione alla sezione "IMPORTANTE!" all'inizio della pagina.
NEDERLANDS
Lees de installatie-instructies zorgvuldig door voor u begint met de installatie.
U moet vooral het gedeelte waar "BELANGRIJK!" boven staat heel goed lezen.
PORTUGUÊS
Leia cuidadosamente as instruções de instalação antes de prosseguir com a instalação.
Em particular, é necessário ler as informações na secção "IMPORTANTE!" na parte superior da página.
ΕΛΛΗΝΙΚΆ
Διαβάστε τις Οδηγίες εγκατάστασης πριν συνεχίσετε με την εγκατάσταση.
Συγκεκριμένα, θα χρειαστεί να διαβάσετε την ενότητα «ΣΗΜΑΝΤΙΚΟ!» στο πάνω μέρος της σελίδας.
БЪЛГАРСКИ
Прочетете инструкциите за инсталиране преди да продължите с инсталирането.
В частност, ще трябва да прочетете раздела „ВАЖНО!" в горната част на страницата.
РУССКИЙ
Перед выполнением установки прочтите инструкцию по установке.
В частности, вам следует прочесть раздел «ВАЖНО!» вверху страницы.
УКРАЇНСЬКА
Перш ніж продовжити встановлення, прочитайте вказівки зі встановлення.
Зокрема, обов'язково прочитайте розділ «ВАЖЛИВО!» вгорі сторінки.
B.INDONESIA
Bacalah seluruh Petunjuk Pemasangan sebelum Anda melakukan pemasangan.
Secara khusus, Anda perlu membaca bagian "PENTING!" di bagian atas halaman.
F616380
AMP Air Conditioning
www.ampair.co.uk | sales@ampair.co.uk

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic S-15MK2E5A

  • Page 1: Installation Instructions

    Rated Capacity Indoor Units Type Type Wall Mounted S-15MK2E5A S-22MK2E5A S-28MK2E5A S-36MK2E5A ENGLISH Read through the Installation Instructions before you proceed with the installation. In particular, you will need to read under the “IMPORTANT!” section at the top of the page.
  • Page 2: Important

    IMPORTANT! • Provide a power outlet to be used exclusively for each unit. Please Read Before Starting • Provide a power outlet exclusively for This air conditioner must be installed by the sales dealer each unit, and full disconnection means or installer.
  • Page 3 When Connecting Refrigerant Tubing • This product must not be modified or disassembled WARNING WARNING • When performing piping under any circumstances. work do not mix air except Modified or disassembled for specified refrigerant unit may cause fire, electric shock or injury. (R410A) in refrigeration cycle.
  • Page 4: Important Information Regarding The Refrigerant Used

    IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. Refrigerant type: R410A value: 1975 GWP = global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information.
  • Page 5: Table Of Contents

    CONTENTS Page Page IMPORTANT! ........2 6. HOW TO INSTALL TIMER REMOTE CONTROLLER Please Read Before Starting OR HIGH-SPEC WIRED REMOTE CONTROLLER (OPTIONAL PART) .
  • Page 6: General

    1. GENERAL 2. SELECTING THE INSTALLATION SITE This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of 2-1. Indoor Unit instructions for the indoor units and make sure all accessory AVOID: parts listed are with the indoor units before beginning.
  • Page 7: How To Install The Indoor Unit

    3. HOW TO INSTALL THE INDOOR UNIT (3) Double check with a carpenter’s level or tape measure that the panel is level. This is important to install the unit 3-1. Starting the Installation properly. (Fig. 3-3) (1) Remove the rear panel. NOT E Tubing can be extended in 6 directions as shown in Fig.
  • Page 8: Install The Rear Panel On The Wall

    3-4. Install the Rear Panel on the Wall Be sure to confirm that the wall is strong enough to suspend the unit. (1) Make sure the panel is flush against the wall. Any space between the wall and unit will cause noise and vibration. Piping 3-5.
  • Page 9 Install the indoor unit (2) For the Right and Right Bottom Piping Hook the indoor unit onto the upper portion of installation plate. Step 1 Pull out the Indoor piping (Engage the indoor unit with the upper edge of the installation ↓...
  • Page 10: Check The Drainage

    3-7. Replace the Drain Hose (4) In case of left piping how to insert the connection cable and drain hose. (1) Rear view for left piping installation Drain hose Drain cap Drain hose Cable Fig. 3-18 Piping Fig. 3-23 (2) Adjust the piping slightly downwards (For the right piping, follow the same procedure) N OTE Attention not to bend up drain hose...
  • Page 11: Electrical Wiring

    4. ELECTRICAL WIRING 4-2. Recommended Wire Length and Wire Diameter for Power Supply System 4-1. General Precautions on Wiring (B) Power supply cable (1) Before wiring, confirm the rated voltage of the unit as Minimum power shown on its nameplate, then carry out the wiring closely Model Power supply supply cables...
  • Page 12: Wiring System Diagram

    4-3. Wiring System Diagram Indoor unit (No. 1) Power supply Outdoor unit 220/230/240V ~50/60Hz INV unit Ground Power supply 380/400/415V, 3 N~, 50Hz Remote controller Ground Ground Ground Indoor unit Ground (No. 2) Inter-outdoor-unit control wiring Power supply Ground 220/230/240V ~50/60Hz Outdoor unit Ground INV unit...
  • Page 13 CAUTION (1) When linking the outdoor units in a network, disconnect the terminal extended from the short plug from all outdoor units except any one of the outdoor units. (When shipping: In shorted condition.) For a system without link (no wiring connection between outdoor units), do not remove the short plug. (2) Do not install the inter-unit control wiring in a way that forms a loop.
  • Page 14: For Stranded Wiring

    How to connect wiring to the terminal ■ For stranded wiring (1) Cut the wire end with cutting pliers, Stranded wire Special then strip the insulation to expose Screw washer the stranded wiring about 10 mm and Ring tightly twist the wire ends. (Fig. 4-7) pressure Ring pressure (2) Using a Phillips head screwdriver,...
  • Page 15: How To Process Tubing

    5. HOW TO PROCESS TUBING Caution Before Connecting Tubes Tightly (1) Apply a sealing cap or water-proof tape to prevent dust or water from entering the tubes before they are used. 5-1. Connecting the Refrigerant Tubing (2) Be sure to apply refrigerant lubricant (ether oil) to the Use of the Flaring Method surface of a flare before making piping connections.
  • Page 16: Insulating The Refrigerant Tubing

    ● For the flare nuts at tubing connections, be sure to use the Insulation material flare nuts that were supplied with the unit, or else flare nuts The material used for insulation must have good insulation for R410A (type 2). The refrigerant tubing that is used must characteristics, be easy to use, be age resistant, and must not be of the correct wall thickness as shown in the table.
  • Page 17 7. APPENDIX ■ When Using Wireless Remote Controller Instead of Wired Remote Controller When the wireless remote controller is to be used, slide the switch (S011) on the indoor unit control PCB to the ON position. ● If this setting is not made, an alarm will occur. (The operation lamp on the display blinks.) Slide Setting status ON: Wireless: main, Wired: sub...
  • Page 18 Check Before Requiring Services ● Symptom Cause Remedy Press ON/OFF operation button on remote control unit Power failure or after power failure again. Air conditioner does not run at Switch on power if breaker is turned off. ● all although power is turned on. Operation button is turned off.
  • Page 19 F616380 Printed in Malaysia DC1213-0 AMP Air Conditioning www.ampair.co.uk | sales@ampair.co.uk...

This manual is also suitable for:

S-22mk2e5aS-28mk2e5aS-36mk2e5a

Table of Contents