Page 2
Hongdian Technologies Corporation. Trademarks and Permissions and DTU are the trademarks and logos of Shenzhen Hongdian Technologies Corporation. Other trademarks and logos mentioned in this manual belong to other organizations related. Shenzhen Hongdian Technologies Corporation does not own the rights of other trademarks and logos.
Customers In this document, engineers can perform local configuration operation through the built -in Web configuration interface after H3504 MDVR is normally installed, and also can perform remote configuration operation through the platform server after the platform server is connected with the device.
Page 4
H3504 MDVR V20 Parameter Description Chapter Content 1.Summary This chapter briefly introduces H3504 MDVR for you, gives you a preliminary understanding and impression on its parameter. 2.Descriptionof This chapter introduces the detail of the parameter Parameters configuration of H3504 MDVR .
Page 7
H3504 MDVR V20 Parameter Description List of Tables Table 2-1 Description Table of Wireless Network Information Parameters ..............4 Table 2-2 Description Table of WIFI Network Parameters ....................5 Table 2-3 Description Table of Central Server Online Status ................... 5 Table 2-4 Description Table of Video Storage Status ......................
Introduction 1.1 Summary H3504 MDVR parameters include all parameters of the traveling data recorder in actual applying configuration. You can perform local configuration through its Web configuration interface, and also can perform remote configuration through managing the clients by the platform parameters.
Because both configuration interfaces are slightly different, so they are described as follows: Synchronization between Web interface configuration parameters and platform parameters can be realized when H3504 MDVR is connected with the server. Hongdian Corporation...
Page 11
H3504 MDVR V20 Parameter Description Most device parameter configuration on Web configuration interface can be configured only after selecting a related channel. Parameter configuration of specific channel of device on the platform need to select the device channel, then configure related parameters.
H3504 MDVR V20 Parameter Description Description of Parameters 2.1 Status Information 2.1.1 Wireless Network Information Table 2-1 Description Table of Wireless Network Information Parameters Parameter Meaning How to Configure Name Signal 3G/4G Signal Intensity Grade: Device recognizes the signal Intensity...
H3504 MDVR V20 Parameter Description 2.1.2 WIFI Network Table 2-2 Description Table of WIFI Network Parameters Parameter Meaning How to Set Name Signal WIFI Signal Intensity Grade: Device recognizes the WIFI signal Intensity intensity automatically, unknown Strong is displayed when module is not Normal detected or there isn’t WIFI...
H3504 MDVR V20 Parameter Description Parameter Description How to Configure Name Making video No video SD 1 Status Display existing status of the Detect and display existing status SD card 1: of SD card 1 Existing Not existing SD 2 Status...
H3504 MDVR V20 Parameter Description 2.3 Video Play Video pla yba ck page provides channel 1 Channel 4 to four real-ti me video pla yback through the serial port, pla yba ck control buttons : "pla y", "s top", "sound", "swi tch", double -click the full s creen real-time video pla yba ck opera tion.
H3504 MDVR V20 Parameter Description Parameter Description How to Operate Name again when modification is needed Alarm Check corresponding alarm Default status: empty, direct Type type, then search search is for normal boot video corresponding alarm video Move the cursor to select box,...
H3504 MDVR V20 Parameter Description 2.4.3 Video Capture Table 2-9 Video capture parameter list Parameter Meaning How to configure name Snapshot Capture the picture of the currently Click the snapshot button, path playing video and store it in the and select the path where local storage path.
Page 18
H3504 MDVR V20 Parameter Description Parameter Meaning How to configure name Channel Current channel switch control: Select "enable" or "disable" switch and then click "save" button. Enable Default value: enabled. Disable Real-time flow Picture Image sharpness. Dropdown list selection. The format and frame rate of...
Page 19
H3504 MDVR V20 Parameter Description Parameter Meaning How to configure name definition Level 1 click the save button. Level 2 Default value: Rank 1 Level 3 Level 4 Level 5 Picture Current channel primary stream In the input box, enter the...
Page 20
H3504 MDVR V20 Parameter Description Parameter Meaning How to configure name Picture Current channel bitstream quality In the input box, enter the level: image quality level and click the save button. Default value: 352*288 frame rate The current channel video image...
H3504 MDVR V20 Parameter Description Parameter Meaning How to configure name transmission rate, the transmission input box and click the save of image frames per second, and button. the picture is proportional to the Range: 1~25 degree of fluency:`` Unit: FPS (frame / sec)
H3504 MDVR V20 Parameter Description 2.5.3 OSD Setting Table 2-13 Description Table of OSD Setting Parameters Paramet Meaning How to Set Channel Select the channel configuring Select corresponding channel No. Type with OSD in the dropdown menu, configure this channel with stacked items...
H3504 MDVR V20 Parameter Description Time of produces pre-recorded time Alarm Video Alarm Time of delaying video of Alarm Default setting is 60s Delay video from the end of alarm Setting time is 30~7200s Time SD Card Configured SD card 1 serves as...
Number series products are mandatory). conditions. 2.6.2 Central Server Setting H3504 ca n connect wi th two sets of servers independentl y and simul taneousl y. Table 2-16 Description Table of Central Server Setting Parameters Paramet Meaning How to Set...
H3504 MDVR V20 Parameter Description UDP Port server. Configuration is the port number assigned for the platform end. Backup IP address of the backup Enter manually. Server platform server. Standard IP address format. Address Configuration is IP address of the main platform server.
H3504 MDVR V20 Parameter Description Parameter Meaning How to set name threshold Manual input. Table 2-20 Time out parking settings parameter list Parameter Meaning How to set name Set the maximum vehicle Maximum Default value: 14420 parking time. parking Unit: seconds time Manual input.
H3504 MDVR V20 Parameter Description Paramet Meaning How to Set Service Service code of the service Default is empty. Code provider. Service code has been set in the program, need not to fill. If need to fill, please get it from the service provider.
Page 28
H3504 MDVR V20 Parameter Description Paramet Description How to Operate STATION mode Select AP in AP mode, now H3504 MDVR is the server. WIFI When WIFI selects STATION mode, IP can be Selecting STATIC Access got from the server through methods of...
Page 29
H3504 MDVR V20 Parameter Description Paramet Description How to Operate Shared Encryption shared key used by WIFI. Configure according to actual shared key. When the configuration of “Encryption Algorithm” is not “NONE”, display this parameter. Hongdian Corporation...
H3504 MDVR V20 Parameter Description 2.7.3 Ethernet Setting Table 2-24 Description Table of Ethernet Setting Parameters Paramet Meaning How to Set The device can be directly accessed Standard IP address format. Address through the IP address of the device When leaving the factory, Ethernet interface.
H3504 MDVR V20 Parameter Description Paramet Description How to Operate Route Working mode of the route. Default: Automatic Mode Automatic Selecting “Manual” needs to configure gateway Manual type. Gateway In manual mode, need to configure Default: WiFi Type gateway network type...
H3504 MDVR V20 Parameter Description 2.8 Peripheral Management 2.8.1 Serial Setting This series of devi ces support 4 serials, the corresponding pa rameters from COM0 to COM3 a re all same, here onl y introduce the pa rameters of COM0, pa ra meters confi gura tion of other channels ca n refer to the pa ra meter ta ble of COM0.
H3504 MDVR V20 Parameter Description Paramet Meaning How to Set Control Support types as follows: Set matching parameter value according to No flow control access device. Hardware flow control Software flow control Data Serial reception timeout parameters Default: 500ms receptio setting.
H3504 MDVR V20 Parameter Description Paramet Meaning How to Set Heartbe Enter the contents of your May enter according to the heartbeat situation. content heartbe Enter the interval between Default value: 30 heartbeats Unit: seconds interval You can enter different time intervals as needed.
H3504 MDVR V20 Parameter Description Select Selected serials in this Default: RS232_1 Serials application of PTZ. Set according to actual conditions. Options: RS232_1 RS485_1 Controlling channels in this Default: Channel 1 Channel application of PTZ. Select according to channels Options:...
H3504 MDVR V20 Parameter Description Parameter Meaning How to set name • default value: RS232_1 Serial port This TTS application selects selection the serial port. Set up according to the actual situation. Optional: RS232_1 RS485_1 Table 2-32 Y3 fuel consumption sensor application statement...
H3504 MDVR V20 Parameter Description 2.8.3 IO Parameters Setting Si nce the corresponding pa rameters of IO_IN1~IO_IN6 a re same, here onl y introduce the pa rameters of IO_IN1, pa rameters setting of other cha nnels can refer to the pa rameters table of IO_IN1.
H3504 MDVR V20 Parameter Description Si nce the corresponding pa rameters of IO_OUT1~IO_OUT2 a re same, here onl y introduce the pa ra meters of IO_OUT1, pa ra meters setting of other channels ca n refer to the pa ra meters table of IO_OUT1.
H3504 MDVR V20 Parameter Description 2.9.2 Clock Management Table 2-37 Description Table of System Time Setting Paramet Meaning How to Set Types of Methods of configuring device Default: Manual timing Time system time synchronization Select methods of device timing Synchron Server timing according to actual conditions.
H3504 MDVR V20 Parameter Description 2.9.3 Log Management Table 2-38 Description Table of Log Setting Paramet Meaning How to Set Log Type Display the logs according to Default: All logs selected types in categories Click and display the selected types...
H3504 MDVR V20 Parameter Description 2.9.5 2.9.5 configuration management Table 2-40 Configuration management parameter specification table Parameter Meaning How to set name Configurati After you select the file named.Tar, Import on file click Configure import to import the the local...
H3504 MDVR V20 Parameter Description Paramet Meaning How to Set videos, the username is user Password Corresponding new password Reset according to actual to login the configuring conditions. management page account of the device. Confirm Corresponding new password Conform to the password set in the...
H3504 MDVR V20 Parameter Description Table 2-43 Description Table of Power Setting Parameters Paramet Meaning How to Set Power H3504 supports 2 power Default mode: Ignition Mode modes Set power off delay time according Ignition: The device powers to actual conditions.
Page 44
H3504 MDVR V20 Parameter Description Paramet Meaning How to Set Remote Full path of upgrading content Default: Upgradin in the remote upgrading http://mdvr.hongdian.com:52478/fr g Server server. eewifi Address Fill in according to actual conditions. Hongdian Corporation...
Page 45
Create smart things F14 - F16, Tower A, Building 14, No.12, Ganli 6th Road, Longgang District, Shenzhen 518112, China. +86-755-88864288-5 +86-755-83404677 hongdianchina www.hongdian.com sales@hongdian.com Hongdian_China...
Need help?
Do you have a question about the H3504 and is the answer not in the manual?
Questions and answers