A Board Adjustment After Ic003 (Memory) Replacement - Sony TRINITRON KV-ES38N90 Service Manual

Table of Contents

Advertisement

FOR DRC1050(60Hz) MODE
34. Input 525/60Hz signal. Change to DRC-MF: DRC1250.
35. Copy "DAC 00 HCT (DRC1250, 50Hz)" to
"DAC 00 HCT (DRC1250, 60Hz)".
36. Adjust the following items.
Service Item
GEO: 00
VSZ
V SIZE
01
VPS
V POSITION
02
VLN
V LINEARITY
03
SCO
S CORRECTION
04
HSZ
H SIZE
05
HPS
H POSITION
06
PAP
PIN AMP
07
UPN
UPPER CORNER PIN
08
LPN
LOWER CORNER PIN
09
TRZ
TRAPEZIUM
0A
AGL
AFC ANGLE
0B
BOW AFC BOW
DAC
01
HLN
H LINEARITY
02
MDP MIDDLE PIN
03
CCP
LOWER CORNER PIN
04
HTR
HORIZONTAL TRAPEZIUM
37. Repeat step 5, 6 and 8.
FOR DRC100(60Hz) MODE
38. Change to DRC-MF: DRC100 and then adjust the items
listed in no.36.
FOR PIP(60Hz) MODE
39. Change to PIP mode (PIP: ON) and then adjust the items
listed in no.36.
40. Repeat step 5, 6 and 8.
FOR TWIN(60Hz) MODE
41. Change to TWIN: ON
42. Copy "GEO 00 VSZ, 04 HSZ, 05 HPS (PIP 60Hz)" to
"GEO 00 VSZ, 01 VPS, 04 HSZ, 05 HPS (TWIN 60Hz)"
43. Adjust " GEO 09 TRZ".
FOR PROGRAM INDEX(60Hz) MODE
43. Change to PROGRAM INDEX MODE.
44. Copy "GEO 00 VSZ, 04 HSZ, 05 HPS (PIP 60Hz)" to
"GEO 00 VSZ, 01 VPS, 04 HSZ, 05 HPS (TWIN 60Hz)"
45. Adjust " GEO 09 TRZ".
46. Repeat step 5, 6 and 8.
FOR WIDE MODE, DRC1050(60Hz)
47. Change to VIDEO MODE: Input 525/60Hz singal.
48. Change to DRC-MF: DRC1050, WIDE MODE: ON
49. Adjust the items listed in no.36.
FOR WIDE MODE, DRC100(60Hz)
50. Change the VIDEO MODE: Input 525/60Hz signal.
51. Change to DRC-MF: DRC100, WIDE MODE: ON.
52. Adjust the items listed in no.36 and repeat step 5, 6 and 8.
FOR WIDE MODE, PIP(60Hz)
53. Change the VIDEO MODE: Input 525/60Hz signal.
54. Change to PIP: ON, WIDE MODE: ON.
55. Adjust the items listed in no.36 and repeat step 5, 6 and 8.
6-5. A BOARD ADJUSTMENT AFTER IC003
(MEMORY) REPLACEMENT
1. Enter to Service Mode.
2. Press commander buttons 5 and 0 (Data Initialize), and 2
and 0 (Data Copy) to initialize the data.
3. Call each item number and check if the respective screen
shows the normal picture.
In cases where items are not well adjusted, rectify the items
with fine adjustment.
4. Select item numbers "OPB00" (OP1), "OPB01" (OP2) and
respectively set the bit per model with command buttons 3
and 6.
5. Press commander buttons 8 and 0 (Test Normal) to return
to the data that was set on the shipment from the factory.
(This will also cancel Service Mode).
– 59 –
KV-ES38N90
RM-958

Advertisement

Table of Contents
loading

Table of Contents