8. Registers management

Memory Organization

[Web page or Software]
The user must known that a new register value sent
through the communication port is loaded to the running
parameters in RAM and used for the current process. All
these parameters are lost at power-down. It is required
to save them to "User Parameters" or "Factory
Parameters" with the corresponding function.
EEPROM
USER Parameters
Saved
1
2
WRITE
Communication port
(TCP/UDP)
Action Number and description:
1
2
3
4
1
+
5
+
+
3
5
1
EEPROM
FACTORY Parameters
Saved
3
4
RAM
RUNNING Parameters
Main process Control
(TRACKBALL, LCD, KEYPAD)
SaveUserParameters (0x03) function
During standard power-up or calling
RestoreUserParameters (0x04) function
RestoreFactoryParameters (0x05) function
SaveFactoryParameters (0x06) function
[For integrators engineers only]
By pressing "SOS Button" after power-up
By pressing "SOS Button" during power-up