Registers Management; Memory Organization - FiveCo FMod-IPAXESCTRL User Manual

3 axes ethernet control board
Hide thumbs Also See for FMod-IPAXESCTRL:
Table of Contents

Advertisement

8. Registers management

Memory Organization

The user must know that a new register value sent through the
communication port is loaded to the running parameters in RAM and used
for the current process. All these parameters are lost at power-down. It is
required to save them to "User Parameters" or "Factory
the corresponding functions.
Communication port
[Web page or Software]
EEPROM
USER Parameters
Saved
1
2
RUNNING Parameters
WRITE
(TCP/UDP)
Action Number and description:
SaveUserParameters (0x03) function
1
During standard power-up or calling
2
RestoreUserParameters (0x04) function
RestoreFactoryParameters (0x05) function
3
SaveFactoryParameters (0x06) function
4
1
+
[For integrators engineers only]
5
By pressing "SOS Button" after power-up
By pressing "SOS Button" during power-up
3
+
5
+
1
EEPROM
FACTORY Parameters
Saved
3
4
RAM
Main process Control
(TRACKBALL, LCD, KEYPAD)
FMod-IPAXESCTRL User Manual v.1.5
30 / 70
Parameters",
using
ROM
SOS IP
address
5

Advertisement

Table of Contents
loading