Trap Severity Levels - Motorola BSR 2000 Reference Manual

Snmp
Hide thumbs Also See for BSR 2000:
Table of Contents

Advertisement

BSR 2000 SNMP MIB Reference Guide
MIB File
rdn-evtNotifications.mib
(continued)

Trap Severity Levels

Table 4-3
which is most severe, to 7, which is informational:
Level
Severity
1
emergencies
2
alerts
3
critical
4
errors
5
warnings
4-8
Table 4-2 Motorola Private Traps
describes the trap severity levels that are described in this book from 1,
Table 4-3 Trap Severity Levels
Description
Emergency conditions where the system is unusable - reserved for
vendor-specific, fatal hardware or software errors that prevents normal system
operation and causes reporting system to reboot
Conditions where immediate action is needed - a serious failure which
causes the reporting system to reboot
software
malfunctioning
conditions - a serious failure that requires immediate attention and
Critical
prevents the device from transmitting data but the system could recover
without rebooting
conditions - a failure occurred that could interrupt the normal data
Error
flow
arning conditions - a failure occurred that could interrupt the normal
W
data flow
Trap Name
rdnEvtUpcRegTaskMonFailure
rdnEvtUpcRxUnexpectedMsgType
rdnEvtUpcRxUnexpectedMsgSubType
rdnEvtUpcSemCreateFailure
rdnEvtSvcfloNullPtr
rdnEvtSvcfloWriteNextFlowTlvError
rdnEvtSvcfloSidInsertFailure
rdnEvtUbshaCollectionRspMallocError
rdnEvtUbshaTaskSuspended
but is not caused by