DTX-MFM2/GFM2/SFM2 Fiber Modules
Users Manual
Setting
SETUP > Fiber
Loss >
Test Method
18
Downloaded from
Elcodis.com
electronic components distributor
Table 2. Fiber Test Settings (cont.)
Loss results include connections added after referencing. The reference and test connections
determine which connections are included in results. The Test Method refers to the number of end
connections included:
2 Jumper: Loss results include one connection at one end of the link.
1 Jumper: Loss results include connections at both ends of the link. Select this method for connections
shown in this manual. See "About 1 Jumper Connections" on page 19.
3 Jumper: Loss results exclude connections at the ends of the link. Only the fiber loss is measured.
Different standards have different names for the three test methods. See Appendix B for details. The
Technical Reference Handbook provides additional information on test methods.
This setting does not affect loss results. It is only saved with the results to record which method you
used.
This setting does affect the reference and test connection diagrams shown on the tester's display. The
diagrams show connections for the method selected.