Sensor 3 - RDT Informant Installation And User Instructions Manual

Informant is a self-contained alarm and logging device
Table of Contents

Advertisement

Use of Door Sensor and Panic Buttons
Typical Wiring: Door Position
Sensors,Panic Button and Panic Reset
Door
Sensor
Panic
Button
Reset
Lighting Sequence Table
Door Position:
Opens:
Closes:
Open Too Long:
Panic Button Pressed:
Panic Reset Button Pressed: Alarm silenced.
Interior Lighting
Inside Panic Button
Conduit and Junction Boxes
Sensors or Switches
Side View of Refrigerated Area
Actions
Lights go on.
Door open timer starts running. (0 - 99 min.)
Lights go out.
Timer resets
Alarm horn sounds. (Delay time exceeded.)
Text message alerts sent.
Alarm horn sounds.
Interior lighting turns on.
Text message alarm sounds.
Text message sent "Alarm cleared"
Lights go out.
The
The door sensor (magnetic switch)
auto
automatically controls the internal
ligh
lighting. Once the door is opened
an i
an internal timer in the Informant
starts running. If the door is closed
star
prom
promptly the lights are shut off. If
the door is opened too long a series
of events begins as described in the
table below.
Additionally, an internal panic
button can over-ride the timer.
The external Panic Button Resert
cancels the Internal Panic Button.
6