Check Power Head Mounting Area; Check Ceiling For Grounded Power Source - Overhead door PowewrMax XL 4060 Operation And Maintenance Manual

Dc powered screwdrive opener. with codedodger remotecontrol and series ii electronics
Table of Contents

Advertisement

C
Check Step 5:
HECK
M
Check ceiling or space above where Opener Power Head will be
mounted (Figure 5):
A
Measure from garage door center line mark toward rear
of garage:
Approximately 10' back if garage has a 7' 6" door.
Approximately 11' back if garage has an 8' 0" door.
Mounting Straps are included to attach the Opener to most
garage ceilings. Garage construction varies widely.
Additional mounting straps or angle iron may be needed for
your installation.
B
Find location of ceiling joist or truss above where Opener
Power Head will be and estimate type and quantity of
materials needed for your installation (Figure 6).
OPEN BEAM CEILING EXAMPLES
Mounting Straps
C
Check Step 6:
P
A
Check that there is a 15 Amp 120 Volt grounded electrical
outlet or grounded permanent wiring box (per building code)
within 3' of Opener Power Head:
If not, an outlet or wiring box must be installed. Contact
a licensed electrician for installation.
If building codes require permanent wiring, Power Head
must be partially disassembled to install appropriate
wiring in place of Power Cord. See Figure 33-Assembly
and Installation Poster.
Permanent wiring must be installed by a Licensed
Electrician. Not all Overhead Door Distributors are Licensed
Electricians. Contact someone who is a Licensed Electrician.
WARNING:
NEVER use extension cords or portable generators. Extension
cords can overheat causing a fire. Portable generators do not
have an output compatable with PowerMax requirements.
For Help, call 1-800-784-5028 or visit www.overheaddoor.com
P
H
OWER
EAD
A
OUNTING
REA
NOTE
Support board added
for longer spans
Figure 6 Mounting methods for open beam and finished ceilings
C
G
HECK
EILING FOR
ROUNDED
S
OWER
OURCE
NOTE
10'
for 7-1/2' doors
11'
for 8' doors
Door Center Line
Figure 5 Check Power Head location
Perforated
Angle Iron
(Angle iron not included)
CHECK FOR 15 AMP, 120 VOLT
GROUNDED OUTLET OR WIRING
BOX WITHIN 3 FEET OF THE
POWER HEAD.
FINISHED CEILINGS
Locate ceiling joists or
trusses using
a stud finder
or similar
device.
Attach angle iron
(not included) to
joists or trusses
through finish material
using Lag Screws.