Error Contents - Fujitsu AUY12LBAB Service Manual

Inverter multi air conditioner cassette type refrigerant r410a
Hide thumbs Also See for AUY12LBAB:
Table of Contents

Advertisement

ERROR CONTENTS

Operation can be checked by lighting and flashing of the grille
display section OPERATION and TIMER lamps.
Perform judgment in accordance with the following.
SWING
TIMER OPERATION
SWING LAMP
TIMER LAMP
(Orange)
TEST RUNNING
When the air conditioner is run by pressing the remote control
unit test run button, the OPERATION and TIMER lamps flash
slowly at the same time.
CHECK ITEMS
1. INDOOR UNIT
(1) Is operation of each button on the remote control unit
normal?
(2) Does each lamp light normally?
(3) Do not air flow direction louvers operate normally?
(4) Is the drain normal?
(5) Is there any abnormal noise and vibration during operation?
2005.07.19
MANUAL
AUTO
OPERATION LAMP
(Green)
(Red)
INDOOR UNIT
Error display
OPERATION
TIMER
lamp
lamp
Blinks
Blinks
Pulses
Blinks
4 times
Pulses
Blinks
6 times
Pulses
Blinks
2 times
Pulses
Blinks
3 times
Pulses
Blinks
5 times
Pulses
Blinks
5 times
Pulses
Blinks
3 times
Pulses
Blinks
4 times
9
Error contents
SWING
lamp
Indoor unit
Goes off
Model information abnormal
(permanent type)
Indoor unit
Goes off
Drain abnormal (permanent type)
Goes off
Indoor fan abnormal
Room air temperature thermistor
Goes off
open circuit
Room air temperature thermistor
Blinks
short circuit
Indoor unit
Goes off
Piping thermistor open circuit
Indoor unit
Blinks
Piping thermistor short circuit
Outdoor unit circuit board error or
Goes off
miswiring between outdoor unit
and indoor unit
Outdoor unit discharge temperature
Goes off
sensor error
Goes off
Outdoor unit piping sensor error
Outdoor unit
Goes off
outdoor unit temperature sensor
error

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aoy18lmak2Auy14lbab

Table of Contents