that the ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up to a
temperature higher than 90° C.
Make sure that you connect the blue neutral ca-
ble to the terminal with a letter "N" on it. Con-
nect the brown (or black) phase cable to the
terminal which has a letter "L". Keep the phase
cable connected at all times.
Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make sure
that the cable section is applicable to the volt-
age and the working temperature. The yellow/
green earth wire must be approximately 2 cm
longer than the brown (or black) phase wire.
Building In
min. 100 mm
min. 55 mm
30 mm
A) supplied seal
B) supplied brackets
www.zanussi.com
min. 650 mm
550 mm
A
B
Caution! Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
30 mm
A
min 20 mm
60 mm
(max 150 mm)
B
A) Removable panel
B) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the indi-
cation and the kitchen unit must be equipped
with vents to let a continuous supply of air. The
electrical connection of the hob and the oven
must be installed separately for safety reasons
and to let easy remove oven from the unit.
50 cm
360 cm
2
120 cm
2
180 cm
2
2
11