LG TCD1870QGS Owner's Manual page 43

Hide thumbs Also See for TCD1870QGS:
Table of Contents

Advertisement

Available languages

Available languages

1.
Pressing the Start button cycles to the next test function.
Number of times
the Start
button is pressed
None
Check the version and code of machine
1 time
GAS TYPE: P2:Og
2 time
PDA CHECK
3 time
Drum Motor runs
4 time
Blower Motor runs
GAS TYPE: GAS valve runs
Drum Motor + Blower Moror + Valve
5 time
LED & KEY CHECK
Press High Temp. button
6 time
Press Med Temp. button
Press Low Temp. button
Press No Heat button
7 time
Test ends.
Door switch
(Drum Motor & Blower Motor &
During check, if the
Heater Off, Buzzer seven times)
Door or LintFilter is
LintFilter switch
open
(Drum Motor & Blower Motor &
Heater Off, Buzzer seven times)
During check, if the
Test goes back at step 3
Door and LintFilter
(Drum Motor on & Blower Motor off &
is closed
Heater off )
NOTE
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
Checking point
PROGRAMMING MODE
Display
LqC 1
Version and code of machine(All LED on)
Display P2:Og, tu:XX, td:XX and tS:XX
alternately. XX is the version number
Ir--
Measured moisture value (70~239)
Blower Motor RPM (~3000)
Display the blower motor RPM and the temperature
inside the drum in Celsius alternately
1.Blower Motor RPM (~3000)
2.Current temperature (5~70)
Version and code of machine
LqC1
dE (the door or lint filter is open. Please close the door
and lint filter completely)
Measured moisture value (70~239)
43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tcd1870cggTcd1870qggTcd1870cgs

Table of Contents