14. Troubleshooting

Indoor failure diagnose
[08] Indoor drainage system failure/float switch circuit on indoor PCB failure
If CN13 is fixed well
  If float switch works 
If water pump works
Check water pump
[1/2/3/4/15] Indoor sensor failure
    If sensor terminal is fixed well
Yes
Yes
Yes
Yes
   If sensor resistor
/characteristic is proper
Yes
Check if PCB is faulty,
if yes, replace it
No
Reconnect
No
No
   If CN4 is 
with AC220V
    voltage
Yes
No
No
       If water
pump is electrified
Yes
Replace water pump
No
Reconnect
No
Replace sensor
39
Modify the wiring 
and the circuit
Check indoor PCB and
replace it if necessary
Modify the wiring
  and the circuit