16 Mb Distance Charts
Number
of MAUs
1
1
221 (67)
2
215 (66)
3
210 (64)
4
205 (62)
5
200 (61)
6
195 (59)
7
190 (58)
8
184 (56)
1
215 (66)
2
210 (64)
3
205 (62)
4
200 (61)
5
195 (59)
6
190 (58)
7
184 (56)
8
180 (55)
1
210 (64)
2
205 (62)
3
200 (61)
4
195 (59)
5
190 (58)
6
186 (56)
7
181 (55)
8
176 (54)
1
189 (58)
2
184 (56)
3
180 (55)
4
176 (54)
5
172 (52)
6
167 (51)
7
162 (49)
8
158 (48)
Figure 17. Maximum distances in feet (meters) for Type 3 cabling.
Type 3 Cable
Number of Wiring Closets
2
3
19 Gauge
212 (65)
207 (63)
204 (62)
202 (62)
199 (61)
197 (60)
194 (59)
192 (59)
189 (58)
187 (57)
184 (56)
182 (55)
179 (55)
22 Gauge
207 (63)
202 (62)
200 (61)
197 (59)
195 (59)
192 (59)
189 (58)
187 (57)
184 (56)
182 (55)
180 (55)
177 (54)
174 (53)
24 Gauge
202 (62)
197 (60)
195 (59)
193 (59)
189 (58)
188 (57)
184 (56)
183 (55)
180 (55)
178 (54)
174 (53)
173 (53)
170 (52)
26 Gauge
182 (55)
178 (54)
175 (53)
173 (53)
171 (52)
169 (52)
166 (51)
165 (50)
162 (49)
160 (49)
158 (48)
156 (48)
153 (47)
Installation
4
5
196 (60)
191 (58)
188 (57)
186 (57)
183 (56)
181 (55)
178 (54)
176 (54)
173 (53)
191 (58)
187 (57)
183 (56)
182 (55)
179 (55)
176 (54)
174 (53)
172 (52)
169 (52)
187 (57)
182 (55)
179 (55)
176 (54)
174 (53)
172 (52)
169 (52)
167 (51)
165 (50)
168 (51)
164 (50)
161 (49)
160 (49)
157 (48)
155 (47)
153 (47)
151 (46)
148 (45)
25