Advertisement

MMA 315G/400G WELDING MACHINE
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MMA 315G and is the answer not in the manual?

Questions and answers

Summary of Contents for Mac Afric MMA 315G

  • Page 1 MMA 315G/400G WELDING MACHINE USER MANUAL...
  • Page 3 Preface This manual includes hardware description and operation introduction of the equipments. For your and other people’s safety, please read the manual carefully. Pay attention Pay attention to the words after the signs below. Sign Description The words after this sign means there is great potential danger, which may cause major accident, damage or even death, if it is not followed.
  • Page 5: Table Of Contents

    CONTENTS SAFETY WARNING ··································································································································· 4 MACHINE DESCRIPTION ························································································································· 9 TECHNICAL PARAMETERS TABLE ······································································································· 10 INSTALLATION INSTRUCTION ··············································································································· 12 OPERATION INSTRUCTION ··················································································································· 14 PANEL FUNCTION INSTRUCTION ········································································································· 15 NOTES OR PREVENTIVE MEASURES ································································································· 16 QUESTIONS TO BE RUN INTO DURING WELDING ············································································· 17 MAINTENANCE ·······································································································································...
  • Page 6: Safety Warning

    SAFETY WARNING The safety notes listed in this manual is to ensure correct use of the machine and to keep you and other people from being hurt. The design and manufacture of welding machine considers safety. Please refer to the safety warning listed in the manual to avoid accidents.
  • Page 7 Please follow the rules below to avoid heavy accidents. ˜ Never use the equipment to do other things but welding. ˜ Follow related regulations for the construction of the input-driven power source, choice of place, usage of high-pressure gas, storage, configuration, safe-keeping of workpiece after welding and disposal of waste, etc.
  • Page 8 Please follow the below notes to avoid fire and explode, etc. ˜ No combustible in welding area. ˜ Keep off combustible when welding. ˜ Keep hot workpiece after welding away from flammable gas. ˜ Do move away the combustible around when weld the dooryard, ground and wall,. ˜...
  • Page 9 Please follow the notes below to avoid gas cylinder toppling over or broken. ˜ Use the gas cylinder correctly. ˜ Use the equipped or recommended gaseous regulator. ˜ Read the manual of gaseous regulator carefully before using it, and pay attention to the safety notes.
  • Page 10 them from the power source and ensure the horizontal of the machine. Do fix the gas cylinder with belt or chain when moving it to avoid body hurt. ˜ Ensure fastness and insulation when lifting the wire feeder through the swing ring for welding. Electromagnetic interference needing attention.
  • Page 11: Machine Description

    MACHINE DESCRIPTION The welding machine is a rectifier adopting the most advanced inverter technology. The development of inverter welding equipment profits from the development of the inverter power supply theory and components. The inverter welding power source utilizes high-power component single tube IGBT to transfer 50/60Hz frequency up to 15KHz, then reduce the voltage and commutate, and output high-power voltage via PWM technology.
  • Page 12: Technical Parameters Table

    TECHNICAL PARAMETERS TABLE Model MMA 315G Parameters Three Phase Three Phase Three Phase Power voltage(V) AC380V±15% AC 415V±15% AC 440V±15% Frequency (Hz) 50/60 50/60 50/60 Rated input current (A) 19.7 No-load voltage(V) Output current(A) 40-315 Rated output voltage(V) 32.6 Force range(A)...
  • Page 13 Model MMA 400G Parameters Three Phase Three Phase Three Phase Power voltage(V) AC 380V±15% AC 415V±15% AC 440V±15% Frequency (Hz) 50/60 50/60 50/60 Rated input current (A) 27.7 25.3 No-load voltage(V) VRD voltage (V) Output current(A) 40-400 Rated output voltage(V) Force range(A)...
  • Page 14: Installation Instruction

    INSTALLATION INSTRUCTION The machine is equipment with power voltage compensation equipment. When power voltage moves between±15% of rated voltage, it still can work normally. When use long cable, in order to prevent voltage form going down, bigger section cable is suggested. If cable is too long, it may affect the performance of the power system.
  • Page 15 Attached components type list Mode MMA 315G MMA 400G Rated current of Power switch ≥2.5mm ≥4mm Input side Cable Output side 35mm 50mm ≥2.5mm ≥4mm Earth cable Electrode holder Electrode holder Electrode holder above 500A is above 500A is suggested.
  • Page 16: Operation Instruction

    OPERATION INSTRUCTION 1. Open the power switch, screen will show set current volume and ventilator is beginning to revolve. 2. Adjust knobs of welding current and arc-striking push, make welding function complies with demands. 3. Generally, welding current is adequate to welding electrode according with as following. Specification Φ1.6 Φ2.0...
  • Page 17: Panel Function Instruction

    PANEL FUNCTION INSTRUCTION MMA 315G /400G Front Panel Layout VRD switch VRD indicator Abnormal indicator Current meter Current adjustment knob ARC force adjustment knob Hot start adjustment knob Positive output terminal Negative output terminal The images shown here are indicative only.
  • Page 18: Notes Or Preventive Measures

    NOTES OR PREVENTIVE MEASURES Environment 1) The machine can perform in environment where conditions are dry with a dampness level of max 90%. 2) Ambient temperature is between -10 to 40 degrees centigrade. 3) Avoid welding in sunshine or drippings. Do not let water enter the gas. 4)...
  • Page 19: Questions To Be Run Into During Welding

    QUESTIONS TO BE RUN INTO DURING WELDING Fittings, welding materials, environment factor, supply powers maybe have something to do with welding. User must try to improve welding environment. A. Arc-striking is difficult and easy to pause: 1. Make sure quality of tungsten electrode is high. 2.
  • Page 20: Maintenance

    MAINTENANCE Remove dust by dry and clean compressed air regularly, if welding machine is operating in environment where is polluted with smokes and pollution air, the machine needs to be cleaned once a month. Pressure of compressed air must be within the reasonable range in order to prevent damaging to small components of inner-machine.
  • Page 21: Troubleshooting And Fault Finding

    TROUBLESHOOTING AND FAULT FINDING Notes: The following operations must be performed by qualified electricians with valid certifications. Before maintenance,please contact with us for professional suggestion. Fault symptom and solution. Fault symptom Solution 1. Make sure power switch is off. Meter doesn’t display, fan 2.
  • Page 22: Appendix Ⅰ Circuit Diagram

    APPENDIX Ⅰ CIRCUIT DIAGRAM...
  • Page 23: Appendix Ⅱ Component And List

    APPENDIX Ⅱ COMPONENT AND LIST MMA 315G...
  • Page 24 Component list Item Quantity Item Quantity roker switch Fan net knob back bottom protection angle Front top protection angle of of right side left side back bottom protection angle Front top protection angle of of left side right side clapboard front panel protection angle rubber ring epoxy sticker...
  • Page 25 MMA 400G...
  • Page 26 Component list Item Quantity Item Quantity Find's dypass Meter Indicator tube Machine bottom Indicator tube Plastic foot Roker switch Back bottom protection angle of Front top protection angle of right side left side Back bottom protection angle of Front top protection angle of left side right side Fan net...

This manual is also suitable for:

Mma 400g

Table of Contents