PRODUCTS INTRODUCTION Congratulations for your purchase. CUT 40 ,CUT 60 are made by international most advantaged invert technology .50Hz/60Hz frequency is inverted to high frequency (frequency is over 100KHz) by V-MOSFET, then reduce voltage and commute current, inverter power supply generates powerful DC welding current through PWM technology. Because inverter technology of switch power is used,volume and weight of main transformer has reduced substantially and efficiency has been increased by 30%.
Pilot arc model HF oscillating HF oscillating Burner inter diameter (mm) Pressure of air compressor (kg) Thickness (mm) 1-12 1-20 Weight (kg) Dimensions (mm) 371×153×232 480×204×303 PANEL EXPLANATION CUT 40 Control panel: CUT 60 Control panel: CUT 60 Control panel: YF-22 A2...
Page 4
The panel picture above is for reference only. If any difference with the real machine, please follow with the real machine. INSTALLATION YF-22 A2...
Air regulator installation and operation Firmly tight and seal the copper air hole at IN and OUT terminal by high pressure rubber tube firmly . Tight and seal the meter with meter face rubber tube. Fix the connecting shelf with screw as the regulator position. Get down the plastic screw and fix the regulator on the shelf.
Input cable connection (enclose installing diagram) 1. Every machine has been disposed a power cable which must be connected to coordinated voltage class in compliance according to input voltage of cutting machine .If cutting machine whose power voltage is 220V is connected wrong to AC 380V, that will cause components of inter-machine are burned up.
It is 1mm from copper tip to work piece (it is further if it is arc-supporting cutter.), press knob of torch and burn and strike arc, sparks of HF arc striking will diminished immediately. User can begin to cut. INSTRUCTION NOTES Operation environment 1.
Voltage automatic compensation circuit will prevent from exceeding allowable arrange .If power voltage is too high, that will damaged to components. User must be carefully. 4. There is a grounding screw, which is marked grounding behind cutting machine. Make sure the mantle is grounded reliably by cable whose section is 6 square millimeter in order to prevent from leaking electrify and bringing electrostatic.
5. If the machine will not be used long time, it should be put in its own packing box and store in dry environment. Check Fault CUT 40 Faults Resolvable Methods 1. Switch indicator is on, fan is not working 1.
Page 10
Check Fault CUT 60 Faults Resolvable Methods 1.Open the air switch, fan does not work and 1.Part of assistant power of control panel is damaged and there is nothing in indicator .knob of torch is out there is no DC output .