Custom Insert Installation With Hood Trims - Thermador VCIN60RP Installation Instructions Manual

Thermador professional 60 inch custom insert
Hide thumbs Also See for VCIN60RP:
Table of Contents

Advertisement

Available languages

Available languages

inches (millimeters)
16" (407)
16" (407)
16" (407)
0-3''
0-3''
0-3''
(0-76)
(0-76)
(0-76)
⅝'' (16)
⅝'' (16)
⅝'' (16)
5
5
17
17
17
/
/
8
8
"
"
(448)
(448)
Custom Insert Installation with
Hood Trims
CAUTION
The hood requires at least two people to lift it
safely.
Hidden surfaces may have sharp edges. Use
caution when handling the appliance. Failure
to do so may result in property damage or
personal injury.
WARNING
To avoid electrical shock hazard, before installing, switch
power off at the service panel and lock the panel to
prevent the power from being switched on accidentally.
1. Turn power OFF at the service panel. Lock service
panel to prevent power from being turned ON.
2. Prepare the ductwork.
a) Refer to "Ductwork Preparation" on page 8.
b) Install metal transition with backdraft damper so
that the flap opens up toward the ceiling. If
necessary, install thermal break and additional
backdraft damper (refer to "Hood Transition" on
page 10).
Installation Instructions
1½'' x 3½'' x 27-13/16''
1½'' x 3½'' x 27-13/16''
1½'' x 3½'' x 27-13/16''
(38 x 89 x 707)
(38 x 89 x 707)
(38 x 89 x 707)
1½'' x 3½'' x 23⅜''
1½'' x 3½'' x 23⅜''
1½'' x 3½'' x 23⅜''
(38 x 89 x 594)
(38 x 89 x 594)
(38 x 89 x 594)
56¼" (1430)
56¼" (1430)
56¼" (1430)
Figure 6: Stud Dimensions
3. Build the housing framework.
a) Refer to "General Information" on page 6 for the
model dimensions.
b) Refer to "Installation" on page 7 for clearance
specifications.
c) Build housing framework for applicable model
according to dimensions in "Preparing the Ceiling
Cutout and Housing" beginning on page 11.
4. Install the hood trim.
e) Hold trim flush to the bottom of the housing.
Secure the trim to the hood with (20) x
screws, as indicated in Figure 7.
The back trim piece may not be necessary in some
installation scenarios where there is a ½''
(12.7 mm) or less space between the hood and the
back wall.
5. Prepare for the wire routing.
a) Remove the junction box cover.
b) Remove circular knockouts.
"B"
'' (9.5 mm)
Figure 7: Trim Installation
"A"
Figure 8: Junction Box Location