Technical Safety - Miele KFN 15943 D edt/cs Operating And Installation Instructions

Table of Contents

Advertisement

Technical safety

The refrigerant system is tested for leaks. This appliance complies
with statutory safety requirements.
This appliance contains the refrigerant Isobutane (R600a), a natu-
ral gas which is environmentally friendly. Although it is combustible,
it does not damage the ozone layer and does not increase the green-
house effect.
The use of this refrigerant has, however, led to a slight increase in
the noise level of the appliance. In addition to the noise of the com-
pressor, you might be able to hear the refrigerant flowing around the
system. This is unavoidable, and does not have any adverse effect
on the performance of the appliance.
Care must be taken during the transportation and setting up of the
appliance that no parts of the cooling system are damaged. Leaking
refrigerant can cause severe irritation to the eyes.
In the event of any damage:
– avoid open flames and anything that creates a spark,
– disconnect the appliance from the electrical power supply,
– ventilate the room where the appliance is located for several min-
utes, and
– contact Miele Technical Service.
The more coolant there is in an appliance, the larger the room it
should be installed in. In the event of a leakage, if the appliance is in
a small room, there is the danger of combustible gases building up.
For every 11 g of coolant at least 1 m
amount of coolant in the appliance is stated on the data plate inside
the appliance.
To avoid the risk of damage to the appliance, make sure that the
connection data (fuse rating, frequency and voltage) on the data
plate corresponds to the household supply.
Check that this is the case before connecting the appliance. Consult
a qualified electrician if in any doubt.
IMPORTANT SAFETY INSTRUCTIONS
3
of room space is required. The
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents