Download Print this page
PCE Americas PCE-DRB 1 User Manual

PCE Americas PCE-DRB 1 User Manual

Refractometer pce-dr series

Advertisement

Quick Links

PCE Americas Inc.
PCE Instruments UK Ltd.
711 Commerce Way
Units 12/13
Suite 8
Southpoint Business Park
Jupiter
Ensign way
FL-33458
Hampshire / Southampton
USA
United Kingdom, SO31 4RF
From outside US: +1
From outside UK: +44
Tel: (561) 320-9162
Tel: (0) 2380 98703 0
Fax: (561) 320-9176
Fax: (0) 2380 98703 9
info@pce-americas.com
info@industrial-needs.com
www.pce-instruments.com/english
www.pce-instruments.com
User Manual
Refractometer PCE-DR Series

Advertisement

loading

Summary of Contents for PCE Americas PCE-DRB 1

  • Page 1 PCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13 Suite 8 Southpoint Business Park Jupiter Ensign way FL-33458 Hampshire / Southampton United Kingdom, SO31 4RF From outside US: +1 From outside UK: +44 Tel: (561) 320-9162 Tel: (0) 2380 98703 0...
  • Page 2 Contents 1. Introduction ------------------------------------------------------------------------------------1 2. Display Areas and Buttons --------------------------------------------------------------1-2 3. Preparations before operating -------------------------------------------------------------2 4. Booting and calibration ----------------------------------------------------------------------2 5. Measurement --------------------------------------------------------------------------------2-3 6. Scales converting and temperature systems converting ---------------------------3 7. Turn off the instrument -----------------------------------------------------------------------3 8. Maintenance and preservation ------------------------------------------------------------3 Appendix 1: Performance / the error codes table ------------------------------------3 Appendix 2: Models and specifications (continued)----------------------------------4 1.
  • Page 3 2.2 The buttons D series has three buttons, respectively is: 1. The “Read” button: for booting / measuring. 2. The “Cal” button: for entering the model of calibrating “Zero Point” 3. The “Scale” button: for converting different scales / converting temperature systems between Celsius and Fahrenheit.
  • Page 4 P5.2 P5.3 If press the "Read" button for 2 seconds, the instrument would make the automatic measurements upon programmed times (default 15 times), the final value is the average of 15 times’ measurements, please see the P5.4. After measurements, the multi-function display area would return back to scale showing status.
  • Page 5 Appendix 2 Models and specifications (continued) Material Model Scale Scale No. Measure Range Resolution Precision PCE-DRB Brix 0-90.00% 0,10% ±0.2% Refractive Index 1.3330-1.5177nD 0.0001nD ±0.0003nD Dextran 0-10.6% 0,10% ±0.2% Fructose 0-68.9% 0,10% ±0.2% PCE-DRB Glucose 0-59.9% 0,10% ±0.2% Lactose 0-16.5% 0,10% ±0.2% Maltose...

This manual is also suitable for:

Pce-drb 2Pce-drw 1Pce-drp 2Pce-drp 1Pce-drs 2Pce-drs1 ... Show all