Programming Defaults/Options
Programming
Programming
Programming
Defaults/Options (Continued)
Defaults/Options
Defaults/Options
Zone Programming Notes
Zone Programming Notes
Zone Programming Notes
Zone Programming Notes
Zones 1-64 are RF Zones (Refer to "SENSORS" in AlarmNet 360)
Zones 65-68 are 5800 Garage Door Zones (Refer to "SENSORS" in AlarmNet 360)
Zones 131-162 are Keyfob Zones (Refer to "KEYFOBS" in AlarmNet 360)
Zones 280-291 are Temperature Zones (Refer to "SENSORS" in AlarmNet 360)
Zones 840 – 847 are reserved for Smart Devices
Zones 850-857 are Keypad Zones (Refer to "KEYPADS" in AlarmNet 360)
Zones 995, 996 and 999 are Panic Zones (Refer to "SENSORS" in AlarmNet 360)
Explanation of Zone Assignment Table Headings
Explanation of Zone Assignment Table Headings
Explanation of Zone Assignment Table Headings
Explanation of Zone Assignment Table Headings
Loop Number - - - - Used with 5800 Devices. Entries are 1-4, depending on device being used. Refer to the transmitter's
Loop Number
Loop Number
Loop Number
instructions or the figure provided for appropriate loop numbers.
Device Type
Device Type- - - - Dependent upon the Zone Number being programmed.
Device Type
Device Type
Response Type/Action
Response Type
/Action - - - - Dependent upon the Device Type that has been selected.
Response Type
Response Type
/Action
/Action
Arm Night
Arm Night – Activate/Deactivate specific Motion Sensors in Night Stay mode (Motion Sensor and Other Response Type
Arm Night
Arm Night
only).
Options: Yes, No
Alarm Report
Alarm Report – Activate/Deactivate reporting option for the device.
Alarm Report
Alarm Report
Options: Yes, No
Description 1/2
Description
1/2 – Enter Zone Descriptors on displayed keypad. System Announces pre-programmed voice descriptors.
Description
Description
1/2
1/2
Supervision
Supervision - Dependent upon the Zone Number being programmed.
Supervision
Supervision
Wireless Zone (Zone 1
Wireless Zone (Zone 1
Wireless Zone (Zone 1- - - - 68
Wireless Zone (Zone 1
68) ) ) )
68
68
RF Supervised
RF Unsupervised
Chime – Enable/Disable chime sounding for the device (applies to Entry/Exit, Perimeter and Interior Response
Chime
Chime
Chime
Types only).
Disabled
Melody Long
Standard
Ascend
Melody
Ascend Long
Device/Response Type Matrix
Device/Response Type Matrix
Device/Response Type Matrix
Device/Response Type Matrix
Device Type
Device T
ype
Device T
Device T
ype
ype
Carbon Monoxide Detector
Door
Environmental
Fire
Flood
Garage Door
Glass Break
Heat Sensor
Medical
Motion Sensor
Other
Police
Smoke Detector
Temperature
Window
Documentation and Online Support
Documentation and Online Support
Documentation and Online Support
Documentation and Online Support
Refer to the following documents for additional information, as required. Copies may be requested from Honeywell.
AlarmNet 360 Online Help Guide (p/n 800-11248 or higher)
Lyric Gateway Getting Started Guide (p/n 800-22261 or higher)
Lyric Gateway Installation and Reference Guide (p/n 800-21666 or higher)
Lyric Gateway User Reference Guide (p/n 800-21670 or higher)
Lyric Communicators Installation Instructions (p/n 800-21145 or higher)
For online documents
For online documents visit
For online documents
For online documents
(Continued)
(Continued)
(Continued)
Key (Zone 131
Key (Zone 131- - - - 162)
Key (Zone 131
Key (Zone 131
162)
162)
162)
Button
Alert 1
Alert 2
Doorbell 1
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
visit
visit: : : : https://mywebtech.honeywell.com.
visit
Temperature (Zone 280- - - - 291)
Temperature (Zone 280
Temperature (Zone 280
Temperature (Zone 280
291)
291)
291)
High Temp
Low Temp
Doorbell 2
Evolve
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
- 7 -
Keypad (850- - - - 85
Keypad (850
Keypad (850
Keypad (850
857 7 7 7 ) ) ) )
85
85
60Min
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Advertisement

loading

This manual is also suitable for:

Lyric lcp300-lc