The following procedure resets the module
programming to the vehicle. It does not reset
any settings confi gured online.
01
Disconnect all connectors from module except
the M1 BLACK 8-pin connector and the M4
BLACK 20-pin connector.
02
Disconnect the M1 BLACK 8-pin connector
and the M4 BLACK 20-pin connector.
03
PRESS AND HOLD the module's programming
button while connecting the M1 BLACK
8-pin connector and the M4 BLACK 20-pin
connector.
04
Wait, LED 1 will flash RED. RELEASE
programming button.
05
LED 1 will turn RED for 2 seconds.
U.S. Patent No. 8,856,780
Automotive Data Solutions Inc. © 2017
MODULE RESET PROCEDURE - 1 OF 1
06
Module RESET completed.
07
Reconnect all connectors.
08
Repeat programming procedure.
>>
Failure to follow procedure may result with a
DTC or a CHECK ENGINE error message.