Kenmore 11029852990 Owner's Manual And Installation Instructions page 11

Three-speed automatic washers
Table of Contents

Advertisement

LAUNDRY TUB DRAIN SYSTEM
Check location where washer will be
installed. This washer can be installed
using one of three systems:
• Laundry tub drain system (below)
• Standpipe drain system (p. 12)
• Floor drain system (p. 12)
Grounded receptacle: Must
be within 4 feet of where the
power cord is attached to the
back of the washer.
Support: Floor must be sturdy
enough to support a total weight
of 315 pounds (including washer,
water, and load weight).
Do not store or operate washer at or
below 32°F (some water may remain in
washer). See page 31 for Winterizing
Information.
Proper installation is your responsibility.
Make sure you have everything necessary
for correct installation including the
following points:
Hot and cold water faucets:
Must provide water pressure
between 5-100 psi and be
within 4 feet of the hot and
cold water fill valves attached
to the back of the washer.
Level floor: Maximum
allowable slope under entire
washer – 1 inch.
Laundry tub drain system:
Needs a minimum 20-gallon
laundry tub.
39"
Top of tub must be at
least 39 inches above
floor and no higher
than 96 inches from
bottom of washer.
11