Restarting The Bru3 (Warm Start) - Ericsson BRU3 Instructions Manual

Hide thumbs Also See for BRU3:
Table of Contents

Advertisement

OPERATION AND MAINTENANCE, MODULE B1
4.
When you are asked to verify the command, enter Y.
5.
The shutdown procedure will stop all incoming traffic and close all open
files. A message will be displayed on the console terminal when the node
may be switched off.
1.3.3

Restarting the BRU3 (Warm Start)

Restart (RESET) can be performed either of the entire node or of certain units.
By command from an NCC operator.
By the NODOP command BOOT using a terminal.
Manually for different units.
Automatically, by the software for the different units.
1.3.4
Manual Restart of the BRU3
The manual restart procedure below should be used only if NODOP does not
respond to any command. Otherwise, use the NODOP BOOT command.
Pressing the reset button will cause an immediate restart of the BRU3, without
ensuring a proper node shutdown. The restart may result in loss of user traffic
and data.
The reset button (SW1) is located on the FE Computer Board (FCB).
After the restart, the BRU3 will be reinitiated, implying logical connection of
all serial communication.
BRU3 MANUAL, Doc.no: 1543-ANNA 805 08 Uen Rev H, 2003-06-10