26
www.electrolux.com
BURNER
Triple Crown
14.5 Gas burners for LPG G30 50 mbar
BURNER
Triple
Crown
Semi-rapid
Auxiliary
14.6 Gas connection
WARNING!
Use this appliance with the
LPG supply at a pressure of
50 mbar. If you supply the
appliance with a lower
pressure, the performance of
the appliance will be not
satisfactory.
The gas pipe in the appliance has two
endings. You can connect the gas supply
to either one of them. The pipe that is not
used must be clogged with the pipe
closer, which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
metallic pipes, make sure they do not
come in touch with mobile parts and they
are not squeezed.
NORMAL
GAS RATE g/h
POWER kW
4.0
2.0
1.0
Ø BYPASS 1/100 mm
REDUCED POW‐
ER kW
290.8
145.4
72.7
14.7 Flexible nonmetal pipes
connection
If you have an easy access to the
connection, you can use a flexible pipe.
The flexible pipe must be tightly attached
by clamps.
In installation always use the pipe holder
and the gasket. The flexible pipe can be
applied when:
• it can not get hotter than room
temperature, higher than 30 °C,
• it is not longer than 1500 mm,
• it has no narrowing anywhere,
• it is not twisted or tighten,
• it does not get in touch with sharp
edges or corners,
• it's conditions can be easily checked.
When checking the flexible pipe make
sure:
• it does not show cracks, cuts, marks
of burnings on the two ends and on its
full length,
• the material is not hardened, but
shows its correct elasticity,
• the fastening clamps are not rusted,
• expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.
55
INJECTOR
MARK 1/100
1.6
0.43
0.35
mm
94
60
43

Advertisement