Prefix Char (Hex.)
Enter the Prefix Char for comparison process.
Prefix Process
Specify the comparison process for the Prefix Length and Prefix Char.
Include Prefix Char: The data will transmit all the Prefix Char which user
entered in Prefix Char (Hex.). If the Prefix Length is 1, then only first Char
will be included.
Only Prefix Char 2: The data will transmit only Prefix Char 2 which user
entered in Prefix Char (Hex.).
Not Include: After the comparison process is complete, the data will be
transmitted without Prefix Char which the user entered in Prefix Char
(Hex.).
Suffix
Specify the Suffix Length and Suffix Process of data.
Notice:
Before you configure the settings of Suffix Length, Suffix Char and
Suffix Process, please remember to tick the Enable option,
otherwise the Suffix function doesn't work.
Suffix Length
Specify the Suffix Length for comparison process. After specify the Suffix
Length, please enter the Suffix Char for process.
Suffix Char (Hex.)
Enter the Suffix Char for comparison process.
Suffix Process
Specify the comparison process for the Suffix Length and Suffix Char.
Include Suffix Char: The data will transmit all the Suffix Char which user
entered in Suffix Char (Hex.). If the Suffix Length is 1, then only first Suffix
Char will be included.
Only Suffix Char 1: The data will transmit only Suffix Char 1 which user
entered in Suffix Char (Hex.).
Not Include: After the comparison process is complete, the data will be
transmitted without Suffix Char which the user entered in Suffix Char
(Hex.).
Description
Chapter 3 Featured Function
Factory Default
FF, FF
Include prefix
character
Disabled
2
FF, FF
Include suffix
character
3 - 1 7