Location Continue
Note :If pipe is to be placed in an underground trench,
check with local codes for required depth and mate-
rial construction.
4. Connect the 3/8" male flare brass fitting (furnished
with campfire) to the 1/2" steel piping making sure
to clean the pipe threads and use Teflon tape or pipe
dope.(FLEX LINE NOT SUPPLIED)
5. Connect the 1/2" female X 3/8" male flare brass
fitting to the 3/8" female brass flare fitting, as
sembled on the right side of the gas line, of the
right side of the campfire.
NOTE: Brass to brassw connections do not require
teflon tape or pipe dope.
(Note: show drawing of hard piping installation.
Children and adults should be alerted to the hazards
of high surface temperatures and should stay away
to avoid burns or clothing ignition.
Young children should be carefully supervised when
they are in the area of the appliance.
Never leave the appliance unattended during
operation.
Clothing or other flammable materials should not
be placed on or near the appliance.
∙ Any guard or other protective device removed for
servicing the appliance must be replaced prior to
operating the appliance
∙ Installation and repair should be done by a quali-
fied service person.. The appliance should be in-
spected before use and at least annually by a quali-
fied service person. More frequent cleaning may
be required as necessary. It is imperative the con-
trol compartment, burners and circulating air pas-
sageways of the appliance be kept clean.
∙ Inspect the fuel supply connection before each use
of the appliance.
Storage of this appliance indoors is permissible only
if it has been disconnected from its fuel supply. (natural
gas line or LP gas)
LOCAL CODES
Install and use heater with care. Follow all local codes.
In the absence of local codes, use the latest edition of
The National Fuel Gas Code, ANSZ223.1, also known
as NFPA54*.
Available from :
American National Standards Institute, INC.
1430 Broadway, New York, NY10018
National Fire Protection Association, INC.
Battery march Park Quincy. MA 02269
Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of
control system and any gas control which has been
under water.
IMPORTANT: Installation of natural gas and LP
should be done by a qualified installer, service
agency or gas supplier.
The appliance and its manual shutoff valve must
be disconnected from the gas supply piping sys-
tem during any pressure testing of the system
at test pressures in excess of 1/2 psig (3.5kPa).
This appliance must be isolated from the gas
supply piping system by closing its manual
shutoff valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig (3.5kPa).