Procom PL600HYLA Owner's Operation And Installation Manual

Procom technology campfire owner's operation and installation manual

Advertisement

Quick Links

OWNER'S OPERATION AND INSTALLATION MANUAL
PL600HYLA/PL600HYLB
60,000BTU/Hr
PN750HYLA/PN750HYLB
75,000BTU/Hr
Manually Controlled
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal injury,
or loss of life.
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
-Shut off supply to the appliance.
-Extenguish any open flames.
-Immediately call your gas supplier. Follow
the gas supplier's instructions.
-If you can not reach your gas supplier, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Save this manual for future reference.
Installer: Leave this manual with customer.
IMPORTANT: Read this owner's manual
carefully and completely before trying to
assemble, operate, or service this heater.
WARNING: Improper installation, adjustment,
alteration, service, or maintenance can cause
injury or property damage. Read the installation,
operating and maintenance instructions
thoroughly before installing or servicing this
equipment
WARNING: For Outdoor Use Only. Do not
use for cooking
1
CAMPFIRE

Advertisement

Table of Contents
loading

Summary of Contents for Procom PL600HYLA

  • Page 1 OWNER’S OPERATION AND INSTALLATION MANUAL PL600HYLA/PL600HYLB 60,000BTU/Hr PN750HYLA/PN750HYLB 75,000BTU/Hr Manually Controlled WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. FOR YOUR SAFETY:...
  • Page 2: Table Of Contents

    GENERAL INFORMATION These instructions are intended as a general guide and do not supersede national or local codes in anyway. Authorities having jurisdiction should be consulted before installation. Installation and provision for combustion and ventilation air must confirm with the national Fuel Gas Code. This campfire has been tested to, and complies with IAS 4-96 1997, U, S, Requirements for Outdoor Gas Fireplace GENERAL INFORMATION………………………………………………………………...2 SAFETY INFORMATION………………………………………………………………...3...
  • Page 3: Safety Information

    SAFETY INFORMATION THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY. IT IS NOT INTENDED FOR INSTALLATION IN ANY BUIDING, GARAGE.OR ENCLOSED STRUCTION. IT IS NOT INTENDED FOR INSTALLATION IN OR ON RECREATIONAL VEHICLES OR BOATS. WARNING: Follow all gas leak procedures in this manual, prior to operation.
  • Page 4 Location Continue Note :If pipe is to be placed in an underground trench, check with local codes for required depth and mate- rial construction. 4. Connect the 3/8” male flare brass fitting (furnished with campfire) to the 1/2” steel piping making sure to clean the pipe threads and use Teflon tape or pipe dope.(FLEX LINE NOT SUPPLIED) 5.
  • Page 5: Installation

    Installation LOGS LIST PL600HYLA PN750HYLA FIG 2 The LOG sets for PL600HYLA/ PN750HYLA PL600HYLB PN750HYLB FIG 3 The LOG sets for PL600HYLB/ PN750HYLB...
  • Page 6 Installation continue Check to make sure you have the correct parts before assembling. Logs: 5 aution: Some of the steel edges may be sharp. Please use caution when assembling the unit. INSTALLATION INSTRUCTIONS: 1. Remove log from inside the box. Please note each log fits the number marked on foam package.
  • Page 7: Operating Heater

    Installation (continue) 11. install the No. # 4 log as indicated on the base (FIG.-9) . Fig. -9 Install the LOG #4 12. Install the No. #5 Log as indicated on the base log (FIG. 10). FIG. -10 Insatll the LOG #5 CONNECTING TO GAS SUPPLY Note: Apply a mixture of liquid soap and water to all joints.
  • Page 8: Maintenance And Storage

    LIGHTING INSTRUCTIONS WARNING:FOR YOUR SAFETY READ BEFOR LIGHTING 1. STOP! Read the safety information above. 2. Make sure manual shutoff valve is fully open. 3. Press in and turn control knob clockwise degree to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas around log set and near floor.
  • Page 9: Product Features

    PRODUCT FEATURES SAFETY PILOT The heater has a pilot with a safety shutoff system. The safety pilot is a required feature for outdoor heaters. It shuts off the heater if flame is extinguished by rough wind. PIEZO IGNITION SYSTEM This heater has a piezo igniter. This system requires no matches, batteries, or other sources to light heater.
  • Page 10: Specification

    ACCESSORIES Purchase the accessories from your local dealer or Parts Central. If they cannot supply these accessories call PRO-COM’s Sales Department at 1-877-886-5989 for referral information. You can also write to the ad- dress listed on the back page of this manual. Model L600HYLA/B Btu (LP/NG)
  • Page 11: Parts List

    PARTS LIST PL600HYLA/PL600HYLB PN750HYLA/PN750HYLB...
  • Page 12 ILLUSTRATED PARTS BREAKDOWN PL600HYLA / PL600HYLB PN750HYLA / PN750HYLB...
  • Page 13: Warranty

    WARRANTY INFOR ATION Model: Serial No. Date Purchased Always specify model and serial numbers when communicating with PRO-COM. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

This manual is also suitable for:

Pl600hylbPn750hylaPn750hylb

Table of Contents