Specification; Troubleshooting - Procom PL600HYLA Owner's Operation And Installation Manual

Procom technology campfire owner's operation and installation manual
Table of Contents

Advertisement

ACCESSORIES
Purchase the accessories from your local dealer or
Parts Central. If they cannot supply these accessories
call PRO-COM's Sales Department at 1-877-886-5989
for referral information. You can also write to the ad-
dress listed on the back page of this manual.
Model
Btu (LP/NG)
Gas Type
Ignition
Inlet Gas Pressure* (In. of water)
Maximum
Minimum
Dimensions, Inches
Stove
17 3/4" x22 7/8"x18 1/8"
Carton
Weight, Lbs
Stove
Shipping Weight
* For purpose of shipment adjustment.
Minimum clearances: Bottom:
Top:
Side /walls (around): 48 inch (1220mm)
OBSERVED PROBLEM
Burner does not light
When ignitor buttons
pressed in, there is no
spark at safety Pilot.
Burner fire does not last.
SPECIFICATIONS
L600HYLA/B
60.000
LP
Piezo
14"
11"
(H x W x D)
15" x25 "x20 1/4"
32/33
55/58
(This appliance may not be place on any combustible materials)
8 FT. (2.4m)

TROUBLESHOOTING

POSSIBLE CAUSE
1.
Air in gas lines.
2.
Inlet gas pressure is too low.
3.
Gas supply turned off.
4.
Air passageway on heater blocked.
5.
Burner orifice clogged.
6.
Control knob not in ING/ON position.
7.
Control knob not fully pressed in while
in ING/ON position.
1.
Ignitor electrode positioned wrong.
2.
Ignitor broken.
3.
Broken ignitor cable.
4.
Ignitor electrode not connected to ignitor cable.
1.
Damaged thermocouple.
2.
Thermocouple electrode corrosion.
3.
Damaged control valve.
4.
Control knob not pressed long enough.
5.
Thermocouple connection loose at control valve.
6.
Pilot flame not touching thermocouple.
HIGH ALTITUDE DERATE
In the U.S.A., Input BTU shall be derated 4%(1 orifice
size) per 1000ft, for above 2000ft.. In Canada, input BTU
shall be derated 10% (2 orifice size) at altitudes from
2000ft.to 4500ft..
PN750HYLA/B
75.000
NG
Piezo
10.5"
5.5"
17 3/4" x22 7/8"x18 1/8"
15" x25 "x20 1/4"
32/ 33
55/ 58
REMEDY
1.
2.
3.
4.
5.
6.
7.
1.
2.
3.
4.
1.Replace thermocouple.
2.
3.
4.
5.
6.
10
Continue holding down control knob.
Repeat igniting operation until air is
removed.
Check gas pressure.
Fully open gas supply.
Check air passageway.
Clean burner.
Turn control knob to ING/ON position.
Press down control knob.
Reposition ignitor.
Replace pilot
Replace ignitor cable.
Connect electrode to ignitor cable.
Clean thermocouple electrode.
Replace control valve.
After pilot lights, keep control knob
pressed in for 30 seconds.
Hand tighten connection or replace
thermocouple.
Contact qualified service man.