Hanna HI 96785C Instruction Manual

Hanna HI 96785C Instruction Manual

Honey color analyzer

Advertisement

Quick Links

Instruction Manual
HI 96785C
Honey Color
Analyzer
w w w . h a n n a i n s t . c o m
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HI 96785C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hanna HI 96785C

  • Page 1 Instruction Manual HI 96785C Honey Color Analyzer w w w . h a n n a i n s t . c o m...
  • Page 2 Dear Customer, PRELIMINARY EXAMINATION Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct use of the instrument. Please read it carefully before using the meter. If Please examine this product carefully. Make sure that the instrument is not damaged. If any you need additional technical information, do not hesitate to e-mail us at tech@hannainst.com.
  • Page 3: General Description

    GENERAL DESCRIPTION SIGNIFICANCE AND USE The HI 96785 is an auto diagnostic portable microprocessor meter that benefits from Hanna’s Honey color varies naturally in a wide range of tonalities, ranging from light yellow to amber, dark years of experience as a manufacturer of analytical instruments. It has the advanced optical amber and black in extreme cases;...
  • Page 4: Specifications

    ±2 mm Pfund @ 80 mm Pfund bandwidth should be selected as well as a proper central wavelength to optimize measurements. Typical EMC Deviation 1 mm Pfund The optical system of Hanna's HI 96 series colorimeters is based on special subminiature Light Source Tungsten lamp...
  • Page 5: Functional Description

    FUNCTIONAL DESCRIPTION ERRORS AND WARNINGS The instrument shows clear messages when erroneous condition appears. Messages are also displayed INSTRUMENT DESCRIPTION when the obtained values are outside expected range. The beeper is playing a beep on errors. 1) CAL key 2) READ key a) on calibration 3) ON/OFF key 4) Liquid Crystal Display (LCD)
  • Page 6: Errors And Warnings

    Under range: A blinking “0” indicates that the sample absorbs GENERAL TIPS FOR AN ACCURATE MEASUREMENT less light than the calibration reference. Check the procedure and recalibrate the instrument. The instructions listed below should be carefully followed during testing to ensure best accuracy. Over Range: A flashing value of the maximum concentration •...
  • Page 7: Startup

    • Press CAL and the lamp, cuvette and STARTUP detector icons will appear on the display, depending on the measurement phase. Prepare the instrument for measurement as follows: • Unpack the instrument by removing the dust protection sleeve from the instrument cuvette •...
  • Page 8: Battery Management

    BATTERY REPLACEMENT If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service Department and then send it with shipment costs prepaid.

Table of Contents