XP-SP30
Pin No.
Pin Name
72
FG_I
73
PGMSEL_O
74
PWRSW_O
75
XPOWLT_O
76
CHGGND_SL_I
77
XOPSTBY_O
78
OPGSW_O
79
XRESET_O
80
C2POEN_O
22
I/O
I
FG pulse signal input from BH6580KV(IC201)
O
Not used
O
Power supply control output of TA2120FN(IC701) ("H":ON)
O
Latch signal output to BH6580KV(IC201)
I
Not used (connected to ground)
O
Optical-pick up voltage control output ("H":gain up)
O
RF AMP gain control output ("H":gain up)
O
Reset signal output to BH6580KV(IC201) and CXD3048R(IC402)
O
Not used (open)
Description