Hardware Management Subsystem; Hardware Monitor Component; Fan Control And Monitoring - Intel D850GB Technical Product Specification

Desktop board
Hide thumbs Also See for D850GB:
Table of Contents

Advertisement

Intel Desktop Board D850GB Technical Product Specification

1.11 Hardware Management Subsystem

The hardware management features enable the board to be compatible with the Wired for
Management (WfM) specification. The board has several hardware management features,
including the following:

Fan control and monitoring

Thermal and voltage monitoring
For information about
The WfM specification

1.11.1 Hardware Monitor Component

The hardware monitor component provides low-cost instrumentation capabilities. The features of
the component include:
Internal ambient temperature sensing
Remote thermal diode sensing for direct monitoring of processor temperature
Power supply monitoring (+12, +5, +3.3, +2.5, 3.3 VSB, Vccp) to detect levels above or below
acceptable values
SMBus interface
1.11.2 Fan Control and Monitoring
The SMSC LPC47M102 I/O controller provides one fan tachometer input. The enhanced thermal
monitor and fan control device provides two fan sense inputs and two fan control outputs.
Monitoring and control can be implemented using third-party software.
For information about
The functions of the fan connectors
The location of the fan connectors
The signal names of the fan connectors
32
Refer to
Table 3, page 16
Refer to
Section 1.12.2.2, page 38
Figure 10, page 56
Section 2.8.2.2, page 54

Hide quick links:

Advertisement

Table of Contents
loading