C
O
M
M
E
R
C
Diagram 14
Secure the
fasteners and
replace the
hood.
Alternately
tighten four
side upright
screws.
Alternately
tighten the four
front panel
screws.
Alternately tighten
the four screws
that secure the
display console.
12. Replace the hood. Diagram 14. Reposition the hood on the treadmill and replace
the four buttonhead screws removed in step 4. The two screws with washers are
placed through the front panel. Tighten the screws using the 3/16-inch hex key.
13. Tighten all mounting screws with the hex keys provided. Diagram 14.
Start at the front of the treadmill with the four screws that attach the upright
supports to the front panel. Tightening these screws first helps pull the rest of
the treadmill's parts into alignment. Then, proceed with tightening the four screws
(D) that secure the upright supports, the four console assembly screws (A), the
handrail assembly screws (A) and (C), and the hood screws.
Adjust the level
Diagram 15
of the treadmill.
Bubble level
Running belt
Adjustable rear
foot
14. Level the unit. Diagram 15. The C956 or C954 has adjustable rear feet. Check
to make sure that the running surface is level (use a bubble level as shown in
Diagram 15). If the treadmill is placed on a slightly, uneven surface, adjusting
the rear feet can help, but will not compensate for extremely uneven surfaces.
Important: If you need to make adjustments, adjust one rear foot at a time.
Do not use the rear foot to raise or lower the unit more than ¾-inches. Check
the level of the unit after each adjustment.
I