REGULATION OF AIR SUPPLY TO OVEN AND GRILL BURNERS
Using a cross-head screwdriver, slacken the screw securing the air flow regulation
collar (fig. 10.10 and 10.11) and move the collar forward or backward to increase or
reduce the air aperture in accordance with gas type and the indications in the " TABLE
FOR THE CHOICE OF THE INJECTORS ".
Light the burner and check the flame.
Fig. 10.11
Fig. 10.10
Ring opening