Model 8067
Instrument User Manual
MINT-0313-XX

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8067 and is the answer not in the manual?

Questions and answers

Summary of Contents for Matheson 8067

  • Page 1 Model 8067 Instrument User Manual MINT-0313-XX...
  • Page 2: Declaration Of Conformity

    8067 MANUAL Matheson Tri-Gas Declaration of conformity Product description: a handheld micro thermal conductivity sensor used to detect gas leaks. This instrument has been designed specifically for search and location of non-flammable gases such as helium and CFC’s. Directives: 2004/108/EC Electrical Equipment –...
  • Page 3: Table Of Contents

    Responsibility of use ............................4 Disposal ................................. 4 Calibration Facility ............................4 Legal Notice ..............................4 Instrument description ............................ 5 Packing List ..............................6 How 8067 works ............................... 7 Thermal Conductivity ............................. 7 Instrument main menu ............................ 8 Functions ................................ 10 Contrast ..............................10 Backlight ..............................
  • Page 4: Statements

    The 8067 can detect a large range of gases but some gases are more difficult to detect. It is the responsibility of the user to ensure the 8067 instrument has the sensitivity to detect the required gas before reaching potentially dangerous levels.
  • Page 5: Instrument Description

    All 8067 models have an easy to use graphical interface with an intuitive keypad allowing simple function selection and adjustment. The 8067 can be upgraded to add features without the need to be returned to the supplier and without having to modify the internal firmware.
  • Page 6: Packing List

    Should the instrument or any accessory appear damaged or missing then contact the instrument supplier for advice before use. Item Description Check 8067 instrument with short probe and nozzle fitted Long probe Box spanner used to change probes Spare battery clip User Quick Start-up manual...
  • Page 7: How 8067 Works

    6 times faster. The 8067 contains a heated thermistor bead that transmits heat to a block of material that remains at a constant temperature. As air passes through the detector chamber a constant amount of heat passes from the bead to the block.
  • Page 8: Instrument Main Menu

    Instrument main menu Once the 8067 has run through its 'Start up' routine, it will display its normal 'Running screen' used when locating gas leaks. Before using the instrument the various settings should be set and adjusted to suit the application.
  • Page 9 The 8067 displays the gas being measured in the top left of the running screen. The 8067 will display the gas selected at the factory only, however the 8067 model has a range of gases that can be selected via an internal gas table.
  • Page 10: Functions

    Functions The 8067 instruments have a variation of functionality, Contrast Use this function to adjust the contrast of the 8067 LCD (Liquid Crystal Display). Significant variations in ambient temperature conditions can cause the display to appear too dark or feint.
  • Page 11: Battery Selection

    'ENTER' key until the data is deleted. Press the 'Esc' key to exit to the Main menu. Units 8067 instruments have the capability of displaying detected readings in a variation of units; ppm, cc/s, mg/m and g/yr.
  • Page 12: Gas Selection

    Functions Gas selection 8067 is calibrated using Helium gas at time of manufacture, however other gases can be detected and measured using a gas table within the instrument. Although 8067 can't differentiate between gases it can quantify other gases using response factors stored in its internal gas table.
  • Page 13: The Keypad

    8067 MANUAL Matheson Tri-Gas Getting started The Keypad All 8067 models have the same keypads, the following section explains the general functionality of each key:- ESCAPE This key is used to return the display to Use the UP key to scroll...
  • Page 14: Using The 8067

    Ensure the instrument is on the X100 (times one hundred) range, while on the main running screen use the UP and DOWN key to adjust between sensitivity ranges. X100 is most sensitive, X1 is the least sensitive. Gas leaks tend to occur at pneumatic joints or welded seams, hold the 8067 at a 45 angle to the object being tested and drag the probe along the seam or joint at a rate of approximately 25mm per second.
  • Page 15: Probe Options

    WARNING: Ensure safety guidelines are adhered to when using compressed air. (MATHESON takes no responsibility for injury or damage caused by misuse of compressed air equipment) MINT-0313-XX Page 15 of 21...
  • Page 16: Detecting Leaks

    Avoid touching the brass sensor block with fingers. * The 8067 can detect changes in Humidity and Carbon dioxide, therefore avoid breathing on the probe. * The thin white tube that covers the inner probe should not be removed. This tube ensures a 1mm gap is maintained between the probe and the surface being tested.
  • Page 17: Calibration

    'tick / check' under the 'Custom Cal' symbol and press the ENTER key. The 8067 requires either 5000 ppm Helium concentration or a 0.0005cc/sec (5 E-4 cc/sec) leak rate as a reference. The 8067 automatically selects the type of Calibration media based on which units the instrument already has selected.
  • Page 18: Calibration Procedure Using 'Cc/Sec' Units

    ESC key to start using the instrument or press the ENTER key to recalibrate again. NOTE: * 8067 can detect changes in Humidity and Carbon dioxide, therefore avoid breathing on the probe. WARNING: Great care should be taken to ensure the calibration gas is neither pressurised or restricts flow to the instruments probe.
  • Page 19: Instrument Warranty And Service

    Standard Warranty is one year from date of purchase. Service At Matheson Tri-gas we recommend that all of our gas detection instruments be returned for service and factory calibration once every 12 months. Contact Matheson Tri-gas or your local distributor for service options in your area.
  • Page 20: Instrument Specifications

    8067 MANUAL Matheson Tri-Gas Instrument specifications Operating temperature 0 to 50 °C 32 to 122 °F Storage temperature -25 to 70 °C -13 to 158 °F Instrument case Polyurethane Dimensions L.390 x W.60 x H.50 mm L15.35” x W2.35” x 2.0 “...
  • Page 21: Replacing Parts

    8067 MANUAL Matheson Tri-Gas Replacing parts Part Item Number Long probe 8067-LPR Short probe 8067-SPR Replacement battery holder 3000 8067-BATHDLR Nozzle 8067-NOZ Box Spanner 8067-SPNR MINT-0313-XX Page 21 of 21...