Lexing lx-hs06 Instruction

Home security alarm system

Advertisement

Quick Links

Brief introduction

LX-HS06 is a set of entirely new English home security alarm system, it uses
advanced MCU control and SMD technology. it innovate multiple trade new technique. It
has integration high, reliability good, technology advanced, function mightiness and
operation simple etc. feature. It used abroad in bank, organ, enterprise, army, villa Dom,
and small zone housing network alarm.

Technical parameter

The Main:
Power:12VDC(power adapter convert)
Standby power: DC12V(chargeable battery)
Working frequency: 433MHz
Remote control distance:≥30m
Static current: 150mA
Battery group waiting time: 90min
Factory setting:
System password:000000
User password: 1234
Code: 0000
Report: no report
Working power: DC9V(cascading battery)
Sense distance: 12m
Installing height:2m
4-key remote controller: Working power: DC3V (lithium battery)
Single-key remote controller: Working power: DC12V A23 battery
Door magnetism (LX-DM1): Working power: DC12V A23 battery
Siren: power DC12V, current: <800mA

Basis configuration

the main(DC12V storage battery group include)
Power adapter
(Input 230VAC,output 12VDC,current 1000mA)
4-key remote controller(battery include)
single-key remote controller(battery include)
Sensor emitterLX-AL8(battery include)
Door magnetismLX-DM1(battery include)
Siren
Telephone line

Option unit

Smoke alarm( LX98-RF、 LX728-RF) 、 wired sensor (glass break LX-AL5、 PIR LX-AL6, PIR &glass break LX-AL7, double detectors
PIR LX-AL11)、wired or wireless PIR LX-AL9!

Function

n
4+8 arm zone
LX-HS06 has 4 wired arm zones and 8 wireless arm zones.
n
English display
Its operation and setting all be displayed by English and operation is more convenient and shortcut.
n
Function mightiness
Possessing multiple programmable function setting, operation and setting is simple, standby power for 24 hours.
n
One key operation
You need only press [AWAY] or [HOME] key to set arm/stay, you can also use remote controller to arm/disarm. Under any
state disarming need only pressing user password.
n
Numeral speech
Inner set numeral speech ware, and has 8 section numeral speeches. During operation, it prompt:" System arm", "system
disarm"; during alarming, it can identify detector automatically and transmit alarm info to receiving alarm telephone, like " fire
alarm", " gas alarm", " security alarm", "help alarm".
n
Password popedom
It has [system password] and [user password], the two passwords can be set after entering alarm system but respective
function popedom is different, that is convenient for manager and operator to control alarm system religiously.
n
Long-distance remote control
The alarm can be controlled by keypad and remote controller, by telephone line, it can be long-distance controlled, and fulfill
arm/disarm/monitor hearing function.
Home security alarm system LX-HS06
315MHz
System delay:0sec
Alert: 300sec
Dial times: 3
Vibrant Ring times: 8
Static current: 30μA
Sense angle:110°
Instruction
1pcs
1pcs
2pcs
1pcs
1pcs
2pcs
1pcs
1pcs

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the lx-hs06 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lexing lx-hs06

  • Page 1 Instruction Brief introduction LX-HS06 is a set of entirely new English home security alarm system, it uses advanced MCU control and SMD technology. it innovate multiple trade new technique. It has integration high, reliability good, technology advanced, function mightiness and operation simple etc.
  • Page 2 Intelligent study. Wireless detector study is very simple. The study time need no 1sec. Connection line 1. connect phone line: connect the main to workable phone path. NOTE: if not connect phone line, the main will give"path trouble"prompt. 2. Connect power adapter: the adapter requires: input 230VAC, output 12VDC, and current 1000mA. During AC power is on, standby battery will be charged automatically.
  • Page 3 · function menu 1.Sys level Arm state 1.Level 2.User level 2.Code 1. Sys 1.Arm report 3.Report 2.No report 4.Delay Wired 1. Instant 2. Zone 2. Delay (zone) 1.Smoke 3. 24 HR Disarm state 2.Gas 4.Bypass 3.Panic … Wireless 1. Alert 1.
  • Page 4 —delay <system delay> 4.delay Enter menu 4. relay→LCD display: Input delay After inputting press # key to confirm.** is delay time for away home when arming, it can set to 00~99sec. · arm zone setting 2.zone Press 2 1.Sys 2.Zone 2.Zone 3.Setup 4.Study Enter menu 2.
  • Page 5 —dialing setting enter menu3.call→2.dial→LCD display: Set dial times press # key to confirm ,** is dial times. Factory set is 3 times; network center is not limited by it until center telephone receiving alarm. —vibrant ring setting Input ring times enter menu3.call→3.
  • Page 6 4 . Link up front cover and tighten the screws(see fig.3) out-line hole Fig. 2 Fig. 3 Fig. 1 Sensor emitter LX-AL8 —Jumper setting (like right figure) ·Sense once to emit: after sensing once, the sensor emit signal ·Sense twice to emit: after sensing twice, the Sense once to sensor emit signal , This setting enhance its...