MS Sedco MicroStar blue Installation Instructions

Motion and presence sensor

Advertisement

Quick Links

MicroStar blue Motion and Presence Sensor Installation Instructions
This device complies with part 15 of the FCC Rules Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by MS Sedco could void the user's
authority to operate the equipment.
The microStar blue is the combination motion and presence sensor that provides superior
activation and safety for automatic sliding doors in a single device. The microStar blue
uses patented microwave technology to create two seamless zones within its detection
pattern. The activation zone provides selectable unidirectional or bidirectional motion
detection. The safety zone provides contiguous presence detection at the threshold and
through it when the door is open. The microStar blue's proprietary software will learn the
movement of the door and then ignore it when opening and closing thus allowing the
safety zone to provide protection through the threshold area of the door. Two relay
outputs are standard. Relay output #1 is for the activation (motion) zone and Relay
output #2 is for the threshold safety (presence) zone.
Prior to installing this sensor verify you have the correct version microStar for the
type of door it is being installed on. Match the color-coded microStar logo on the
sensor cover to Chart A below.
microStar red
microStar white
microStar blue
microStar green

Warning w/symbol: Remember to follow these safety precautions:

FCC Compliance

FCC Warning Statement

Product Description

Insert sensor component pictures here

Installation Preparation

(A) microStar Applications Chart
Sliding
Folding
Doors
Doors
X-approach/safety
Swinging
Doors
X-safety
X-approach X-approach
X-approach/safety
Revolving
Doors

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MicroStar blue and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MS Sedco MicroStar blue

  • Page 1 The safety zone provides contiguous presence detection at the threshold and through it when the door is open. The microStar blue’s proprietary software will learn the movement of the door and then ignore it when opening and closing thus allowing the safety zone to provide protection through the threshold area of the door.
  • Page 2 • Shut off power to the automatic door before wiring sensor. • Always ensure wiring is located clear of any moving door parts to avoid damage. • Always be aware of pedestrian traffic. Keep people clear of the work area when setting up or testing the door.
  • Page 3 (F) Main Circuit Board Diagram (with dip switches, adjustment pots, relays, antenna adjustments identified) (G) Dip Switch Settings Chart (Include drawing of dip switches) Dip Switch Positions: 0= Left; 1= Right Default Switch Function Setting Detection Direction 0=Bi-directional 1=Uni-directional Motion Sensitivity 0=Less Sensitive 1=More Sensitive Threshold Safety...
  • Page 4 If the pattern needs any adjustment, the pattern size is adjusted via the Motion Range Pot. Pattern position to the door is adjusted by physically moving the antenna in or out (vertical tilt) and left to right (lateral tilt) as shown (F). Factory settings are ?˚ vertical tilt and 0˚lateral tilt.

Table of Contents