Advertisement

InnoMedia 6328 Quick Reference Guide
InnoMedia MTA6328 Quick Configuration Guide
V2.1 November 2017
1
Copyright © 2016 InnoMedia. All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTA6328 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for InnoMedia MTA6328

  • Page 1 InnoMedia 6328 Quick Reference Guide InnoMedia MTA6328 Quick Configuration Guide V2.1 November 2017 Copyright © 2016 InnoMedia. All rights reserved.
  • Page 2: Table Of Contents

    ND OF TATISTICS ..........................10 COMMANDS RESTORE TO FACTORY DEFAULT ........................12 CLI ................................12 GUI ..............................12 MTA ......................... 13 ESTORE UTTON ON BACK OF APPENDIX B. DIGITMAP USAGE RULES ......................14 Copyright © 2016 InnoMedia. All rights reserved.
  • Page 3: Mta6328 General

    The Main page contains details of the “Firmware Version” and time since last successful provisioning. It also gives the “System Up Time” which shows how long the device is running since it last rebooted or powered-up. Copyright © 2016 InnoMedia. All rights reserved.
  • Page 4: Port Status Screen

    2. You may select the Port Config menu to see other details for each FXS port or line of the device Note: Whatever is configured on the “Port Config” will override what is configured in “Profile Config”. Copyright © 2016 InnoMedia. All rights reserved.
  • Page 5 MTA will only apply the configured rules and ignore the default. You will need to configure these three default if you are using them. (Please refer to 5 for descriptions of digitmap configuration rules.) Copyright © 2016 InnoMedia. All rights reserved.
  • Page 6: Configuring Ip Address

    InnoMedia 6328 Quick Reference Guide 2.4 Configuring IP Address IP address configuration can be done on Interface Setting menu. By default, the device is configured as a DHCP client. Copyright © 2016 InnoMedia. All rights reserved.
  • Page 7: Enabling Provisioning

    This screen allows to enable and configure basic provisioning parameters. Note: Details for Provisioning - Provisioning method selection, encryption type etc must be done from CLI. Please refer to the MTA6328 Admin Guide document for detailed description. 3 Telnet Console Access the MTA CLI console via Telnet requires the input the same ID and Password as those of the WEB console.
  • Page 8: Basic Device & Sip Configuration Info

    Local IP = 172.16.0.135; Local IP Mask = 255.255.0.0; Local Default GW IP = 172.16.0.1; Local Default GW Mask = 255.255.0.0; Primary Domain Name Server = 4.2.2.1; Secondary Domain Name Server = 172.16.0.2; Copyright © 2016 InnoMedia. All rights reserved.
  • Page 9: Enable Debug Trace To Be Sent To Syslog Server

    Command: <Cr> Enter the syslog server IP address. Note that if there is no syslog server configured, the MTA display the messages to the console screen. 3.4 Reboot the MTA system Command: R Copyright © 2016 InnoMedia. All rights reserved.
  • Page 10: Force Sip Account Registration

    Please enter "Y" to Enable it or "Q" to quit: y 3.8 Show All CLI commands Command: H <Cr> Configuration: Operation Database Cd: Configuring DigitMap Cj: Configuring Jitter Buffer Size Ct: Configure FXS Setting Parameters Cs: Configuring SIP Settings Copyright © 2016 InnoMedia. All rights reserved.
  • Page 11 Mh: Show Syslog Mi: Configure SNTP server Mq: Configure Syslog server Mm: Configure Remote Services Mw: Configure Networking Mode Mt: Config Hot phone feature Ms: Config STUN feature Md: Set Time and Date Copyright © 2016 InnoMedia. All rights reserved.
  • Page 12: Restore To Factory Default

    You can restore the unit back to Factory Defaults by doing the following from the Command Line Interface Command Sequence: D1 <Cr> T$ <Cr> Web GUI Navigate to “Restore to Default” under Management category. Copyright © 2016 InnoMedia. All rights reserved.
  • Page 13: Restore Button On Back Of Mta

    MTA. Hold for 5 seconds, and then the unit should reboot in 20 seconds. After this process is done, the provisioning related parameters remain intact and all other parameters are restored to the default values. Copyright © 2016 InnoMedia. All rights reserved.
  • Page 14: Appendix B. Digitmap Usage Rules

    6. 0.T: This will match the digit 0 and, after a time-out of T seconds (defined in the end digit Time-out). 7. The “T” is what specifies that a time-out will be used to determine when to send the digits. (telnet command: Cs. Provisioning tag: Digitmap_Critical_Timeout) Copyright © 2016 InnoMedia. All rights reserved.

This manual is also suitable for:

Mta6328-2re

Table of Contents