PVM-1341 /1342Q/1343MD
5-3.
BA BOARD ADJUSTMENTS (PVM-1342O. PVM-1343MD ONLY)
-BA
BOARD (COMPONENT SIDE) -
SEP270
L403
0265
L405
§:
jB-Yj
IR-Yj
0
0
D
T401
I BELL FILTER I
BA-1
j
NTSC 3.58 MHz ADJUSTMENT (RV292)
I
1.
Receive NTSC 3.58 color-bar signal.
2.
Connect an oscilloscope to pin @ (COMPOSITE
IN)
of BA-2 connector.
3.
Confirm the Y-OUT is 0.87
±
0.5 Vp-p.
4.
Confirm the residual chroma is 35 mVp-p below.
When it is above 35 mVp-p, adjust with RV1 and
T1 inside CFM201 while tracking.
5.
Connect an oscilloscope to pin @ (B-OUD of A-15
connector.
6.
Adjust RV292 (3.58 SUB HUE) so that the BLUE
OUT waveform
level becomes flat as following
figure.
Note: CONTRAST······normal condition
HUE··--··Normal condition
j
NTSC 4.43 MHz ADJUSTMENT (RV291)
I
1.
Receive NTSC 4.43 color-bar signal.
CFM201
RV290
jPHASEI@
CTR210
RV292
j3.58 SUB HUEI@
RV291
EIB
j4.43 SUB HUEI
~
-23-
BA-2
2.
Confirm the voltage on pin@ of CTR210 is above
5.0 V DC, and on pin @ of CTR210 is below 0.1
V
DC.
3.
Connect an oscilloscope to pin @ of A-15 con-
nector.
4.
Adjust RV291 (4.43 SUB HUE) so that the BLUE
OUT waveform
level becomes flat as following
figure.
Note: CONTRAST······Normal condition
HUE··--··Normal condition
j
PAL ADJUSTMENTS (RV290)
I
1.
Receive NTSC 4.43 color-bar signal.
2.
Confirm the voltage on pin@ of CTR210 is above
5.0 V DC, and on pin @ of CTR210 is below 1.0
V DC.
3.
Connect an oscilloscope to pin
®
of BA-2 co-
nnector.
4.
Confirm the Y-OUT is 0.90 ±0.05 Vp-p and the
residual chroma is below 30 mVp-p.
0.90 ±0.05 Vp-p
=l
PVM-1341 /13420/1343MD
5.
ANTI-PAL Adjustment
(RV290)
( 1) Receive the special PAL color-bar.
(2) Connect an oscilloscope to emitter of 0333
on
A board, and adjust RV290 (PHASE) so that R-Y
anti-PAL portion becomes flat as following figure.
Q333
(emitter)
(3) Connect an oscilloscope to emitter of 0330
on
A board, and adjust RV2 inside SEP270 so that
B-Y anti-PAL portion
becomes flat as following
figure.
+ +
I
SECAM ADJUSTMENTS (T401, L403, L405)
J
1.
Receive
SECAM
color-bar.
2.
Bell Filter Adjustment
(T 401)
(1) Connect an oscilloscope to emitter of 0265.
(2) Adjust
T401 (Bell Filter)
so that the chroma
waveform
becomes smooth.
+
3.
Color Balance Adjustment
(L403)
(1) Connect an oscilloscope to pin
(J)
(R-Y)
of BA-1
connector.
(2) Adjust L403 (R-Y) so that the non-colored portion
level becomes flat.
(3) Connect an oscilloscope to pin @ (B-Y)
of BA-1
connector.
-24-
(4) Adjust L405 (B-Y) so that the non-colored portion
level becomes flat.
B-Y