Ocean Signal rescureME MOB1 User Manual page 8

Maritime survivor locating device
Hide thumbs Also See for rescureME MOB1:
Table of Contents

Advertisement

MOB1 USER MANUAL
entered, a second box for a group MMSI will appear. Enter you group MMSI here if
available.
On completion press the Update Device button to proceed.
A new screen with further instructions will appear.
Slide the arming key down to the armed position and fit the
black rubber programming adaptor so that the push button
is over the test key and the aperture is over the clear
indicator window.
To put the MOB1 into programming mode, press the test
key for at least fifteen seconds. The LED will start flashing xxxxxxx. When ready press the
Yes key on screen.
The screen will now change to the programming
mode. Place the MOB1 over the screen so that the
clear indicator window is over the white box. Press
the <F10> key on your keyboard to commence
programming.
When the programming is complete, the screen will
change. Remove the MOB1 and check that the LED
starts flashing green. Turn the MOB2 off by pressing
the Test key for one second. The LED will blink red
twice. Press the <F12> key to exit the programming
mode.
If the programming fails, the Led will start flashing
Red after a short period of time. Turn the unit off and retry.
Return the arming tab to the locked position. Your MOB1 is now ready for use.